Preliminary - Subject to Change Without Notice
AIRCRAFT EQUIPMENT
Grounded Tranline
WIRE:
RG 400
RG 142B/U
24 AWG
20 AWG
16 AWG
24 AWG
18 AWG
24 AWG
24 AWG
CABLE:
AN-22a
AN-20
Revision 0
10640I00.SLK
N
KHF 1050 SYSTEM INSTALLATION MANUAL
Equipment Required But Not Supplied
Grounded tranline: Towel bar with 1
inch diameter recommended. Contact:
Trivec-Avant Corp.
17831 Jamestown Ln.
Huntington Beach, CA 92647
714-841-4976
Available as:
Double shielded coax P/N 024-00075-0000
Double shielded coax P/N 024-00002-0000
Single conductor P/N 025-00029-0009
Single conductor P/N 025-00031-0000
Single conductor P/N 025-00031-0003
Single conductor with shield and jacket
P/N 025-05018-0000
Single conductor with shield and jacket
P/N 025-05019-0000
Two conductor with shield and jacket
P/N 025-05020-0000
Three conductor with shield and jacket
P/N 025-05023-0000
755 Nominal Circular Mil Area*
0.090 inches Max. Overall Diameter
16.45 ohms Max. per 1000 feet @ 20°C
8 amps Max. Cont. Current Rating**
5 amps Max. Cont. Current Rating***
1,200 Nominal Circular Mil Area*
0.100 inches Max. Overall Diameter
10.25 ohms Max. per 1000 feet @ 20°C
11 amps Max. Cont. Current Rating**
7.5 amps Max. Cont. Current Rating***