Start-up, Inspection and Maintenance

Setup Menu Overview

Item # Function
Filling
1
(see page 40)
Reduce max.
2
heating output
(see page 45)
Altitude setting
3
(see page 45)
4
Do not adjust!
Fuel Type
5
(see page 42)
6
Do not adjust!
Parameter reset
7
Outdoor Temp.
8
Sensor
Button Tone
9
Backlight Display
10
- Standby Mode
Display Contrast
11
Eco/Comfort
12
(B1KA Only)
(see page 46)
Temperature Unit
13
(see page 46)
DHW sensor type
14
(B1HA)
(see page 46)

Filling and Bleeding the Heating System

CAUTION
Unsuitable fill water increases the level of deposits and
corrosion, and may lead to damage to the equipment.
Thoroughly flush the entire heating system prior to
 
filling with water.
Only use fill water of potable quality.
 
Soften fill water harder than 150 ppm temporary
 
hardness.
Inhibitors or antifreeze additives suitable for heating
 
systems may be added manually.
Activating boiler pump (bleeding program)
1. Close the gas shut-off valve.
2. Switch ON the power supply.
3. Tap MODE.
40
Setting Options
0 - Fill mode OFF
1 - Fill mode ON
00 -Low fire (25%)
26-99 - Modulation Range
(26-99%)
100 - High fire (100%)
0 - < or = 5000 ft (1500 m)
1-5 - Do Not Adjust
6 - > 5000 ft (1500 m)
--
0 - Natural Gas
1 - LPG
--
1 - Vitodens 100-W B1KA-35
2 - Vitodens 100-W B1HA-26
3 - Vitodens 100-W B1HA-35
4-99 - Do Not Adjust
0 - NTC 10K Ohm
1 - Do not Adjust
0 - On
1 - Off
0 - Dimmed
1 - Off (no back)
0-6
0 - Eco
1 - Comfort
0 - °C
1 - °F
0 - DHW Temp. Sensor (NTC
10K Ohm)
1 - Aquastat (Dry Contact)
Vitodens 100-W, B1HA series & B1KA Combi Installation/Service
Description
After pressing 'OK' the filling function is active. This
process will automatically terminate after 30 min.
The max. heating output can be adjusted according
to the requirements of the system. The adjusted
heating output should be tested by measuring the gas
throughput.
Adjusts the boiler for high altitude operation.
The gas type can be converted from natural gas to LPG.
Conversion kit is required.
The parameter is fixed based on the boiler type and size.
When replacing the boiler control, refer to boiler rating
on the boiler to set model and size. After adjusting
the parameter cycle the boiler power and verify the
parameter setting.
The right outside temp. sensor has to be adjusted.
The signal tone for display operation can be switched
off.
The display backlighting for standby is either dimmed or
off.
The display contrast is adjustable from 0 to 6. The
higher the value, the greater the contrast.
The comfort function makes DHW available faster at the
selected set DHW temperature. Only available Vitodens
100-W B1KA
The temperature displayed can be set to °C (Celsius) to
°F (Fahrenheit).
The boiler either works with a tank sensor (NTC
10kOhm - Supplied) or with a tank aquastat (field
supplied)
4.
/ until CONFI flashes.
5. OK to confirm.
"P" appears in the left hand display area. The right
hand display area flashes.
6. Use / to select "12".
7. OK to confirm.
"1" flashes in the left hand display area.
8. OK to confirm.
"0" flashes in the right hand display area.
9. Use / to select "1".
10. OK to confirm.
Filling is activated. The boiler circuit pump is running,
the 3-way diverter valve moves to its centre position.
This function terminates automatically after 30 min.
or when the ON/OFF switch is switched off.
--
--
Default
Setting
0
00
0
0
0
0
#
0
0
0
3
0
1
0