Connections
Installation Examples

Built-in pump

Grundfos UPS15-78 three speed heating circuit/DHW production pump for Vitodens 100-W B1HA 26/35 and B1KA 35
boilers (in the factory setting, the pump speed is preset to 'speed three')
Pump Model
Rated voltage
Rated current
Capacitor
Power consumption
Built-in pump, Grundfos UPS15-78 residual head pressure
Residual head of built-in pump at speed 3 (factory set).
26
(continued)
Speed One
Grundfos UPS15-78
VAC
A max.
A min.
F
W max.
W min.
Vitodens 100-W, B1HA series & B1KA Combi Installation/Service
Speed Three
Speed Two
Flow
115
1.15
0.8
8
130
80