Technical Data
(continued)
Standard heating boiler
(continued)
Gas supply connection
5
Flue gas
Temperature at boiler
return temperature of
86ºF (30ºC)
-
at rated full load
-
at rated partial load
Temperature at boiler
return temperature of 140ºF (60ºC)
Flue gas value
Mass flow rate (of flue gas)
- at rated full load
- at rated partial load
Available draught
Flue gas temperature
sensor limit
Average condensate
flow rate
6
with natural gas
- T
/T
=122 / 86ºF (50 / 30ºC)
S
R
Condensate
connection
7
Boiler flue gas
connection
8
Combustion air supply
connection
8
Noise level (at 1 meter)
- at full load
- at partial load
High altitude (factory set)
5
Measured flue gas temperature with a combustion air temperature of 68°F (20°C).
6
Based on typical boiler cycles, including partial load conditions.
7
Requires 1 in. (25 mm) tubing. See Vitodens 100-W Installation Instructions for details.
8
For detailed information refer to the Vitodens Venting System Installation Instructions.
9
For 5,000 to 10,000 ft. (1,500 to 3,000 m) operation, a control programming change is required.
Refer to the Installation and Service Instructions for details.
Note: For altitude operation up to 4,999 feet, derate the input capacity by 3%/1000 ft. (305 m).
For operation from 5,000 to 10,000 ft. (1,500 to 3,000 m), with the electronic altitude adjustment made,
derate the input capacity by 3% for every 1000 ft. (305 m) starting at 5000 ft. (1,500 m) for a total of 15%.
Legend
A Input capacity after electronic altitude adjustment is made.
Boiler Model No.
NPTM (male)
USG/day
in (mm)
coaxial
outer Ø in (mm)
single
9
B1HA 26
c in.
ºF (ºC)
113 (45)
ºF (ºC)
95 (35)
ºF (ºC)
167 (75)
lbs/h
79.2
kg/h
36.0
lbs/h
33.0
kg/h
15.0
Pa
100
mbar
1.0
ºF (ºC)
230 (110)
1.95-2.3
L/day
8-9
hose
nozzle
Ø in
1
Ø
2e (60)
4 (100)
2e (60)
(dB)
46.9
(dB)
41.1
ft. (m)
Additional Information
B1HA 35
c in.
113 (45)
95 (35)
172 (78)
100.1
45.5
33.0
15.0
100
1.0
230 (110)
230 (110)
2.5-2.8
9.4-10.5
1
2e (60)
4 (100)
2e (60)
51.6
41.1
0-5,000 (0-1,500)
B1KA 35
c in.
113 (45)
95 (35)
172 (78)
100.1
45.5
33.0
15.0
100
1.0
2.5-2.8
9.4-10.5
1
2e (60)
4 (100)
2e (60)
51.6
41.1
67