  • Page 1 5 SERIES MOTORIZED ® Owner’s Manual INSTALLERS: PLEASE BE SURE TO LEAVE THIS MANUAL WITH THE OWNER. THANK YOU!
  • Page 2: Limited One-Year Warranty

    APPLY S/N STICKER HERE ® LIMITED ONE YEAR WARRANTY ON SCREEN INNOVATIONS PRODUCTS Screen Innovations warrants its products to the original purchaser only, to be free from defects in materials and workmanship for a period of one (1) year from the date of purchase by the original purchaser provided they are properly operated according to Screen Innovations’...
  • Page 3 5 SERIES MOTORIZED 512-832-6939 9715-B Burnet Road Suite 400, Austin,TX 78758 SCREENINNOVATIONS.COM 0106165SM ®...
  • Page 4: Projector Placement

    5 SERIES MOTORIZED Projector Placement Better 11° Best 11° Good 36”-42” (91cm - 106cm) ®...
  • Page 6 5 SERIES MOTORIZED External Flush L Bracket Flush Suspended ®...
  • Page 7 Flush L Bracket 6’’ x 12’’ (15.24 cm X 30.48) It is highly recommended to provide a 6’’ x 12’’ access panel at the left end of the case and/or make sure the left end of the case can be accessed from inside the ceiling or attic.
  • Page 8: Frame Installation

    Frame Installation Flush L Bracket ®...
  • Page 9 Case Opening Flush L Bracket in/cm in/cm ” 3/4” (0.635 cm) (4.5 cm) ” 3/4” (0.635 cm) (4.5 cm) 0106165SM ®...
  • Page 10 Flush L Bracket 200 lbs (90gk) 7” - 2” 7” - 2” (17.8 cm - 5 cm) (17.8 cm - 5 cm) 1/4” (18.4 cm) 3/8” (18.7 cm) Ceiling ®...
  • Page 11 Flush L Bracket 110V White NEUTRAL 220V Blue 110V Black 220V Brown 110V Green GROUND 220V Green and White If there is not an access panel at the left end of the case in the ceilng, or access from above via the ceiling or attic; then you must make sure to make all power and control connections before proceeding.
  • Page 12 Flush L Bracket ®...
  • Page 13 Flush L Bracket 0106165SM ®...
  • Page 14 Flush L Bracket ®...
  • Page 16 Frame Installation External ®...
  • Page 17 External 200 lbs (90 kg) Evenly Spaced If more than 2 brackets included 7”- 2” 7”- 2” (17.8 cm - 5 cm) (17.8 cm - 5 cm) 0106165SM ®...
  • Page 18 External ®...
  • Page 19 External 0106165SM ®...
  • Page 20 Frame Installation Flush Suspended ®...
  • Page 21 Flush Suspended 6’’ x 12’’ (15.24 cm X 30.48) It is highly recommended to provide a 6’’ x 12’’ access panel at the left end of the case and/or make sure the left end of the case can be accessed from inside the ceiling or attic. Parts to be supplied by installer Threaded Rod 3/8’’...
  • Page 22 Case Opening Flush Suspended in/cm in/cm ” 3/4” (0.635 cm) (4.4 cm) ” 3/4” (0.31 cm) (4.5 cm) ®...
  • Page 23 Flush Suspended Stuctural Member 4” - 12” 4” - 12” (17.8 cm - 5 cm) (17.8 cm - 5 cm) Ceiling 0106165SM ®...
  • Page 24 Flush Suspended Small Case '' Approx 15/16 Large Case '' Approx 15/16 Threaded Rod Minimum 3/8’’ Supplied By Installer Washer Washer ®...
  • Page 25 Flush Suspended 110V White NEUTRAL 220V Blue 110V Black 220V Brown 110V Green GROUND 220V Green and White If there is not an access panel at the left end of the case in the ceilng, or access from above via the ceiling or attic; then you must make sure to make all power and control connections before proceeding.
  • Page 27 Flush Suspended 0106165SM ®...
  • Page 28 IEC Connection ®...
  • Page 29 Pigtail Connection 110V White NEUTRAL 220V Blue 110V Black 220V Brown 110V Green GROUND 220V Green and White 6ft (1.83m) 0106165SM ®...
  • Page 30 Controls RJ45 Inputs (3X) Low Voltage Trigger Input (1/8’’ (3.5mm) mono) RJ45 Input inside case ®...
  • Page 31: Setting The Lower Limit

    Setting the Lower Limit Wall Switch 9 ft (2.75m) Provided RJ45 If Longer cable must be shielded Desired Drop Projected Image 0106165SM ®...
  • Page 32: Wall Switch General Operation

    Wall Switch General Operation SET LOWER LIMIT NORMAL OPERATION SET UPPER LIMIT ®...
  • Page 33 Reverse Screen Direction 0106165SM ®...
  • Page 34 Reverse Screen Direction SET LOWER LIMIT NORMAL OPERATION SET UPPER LIMIT SET LOWER LIMIT NORMAL OPERATION SET UPPER LIMIT 1..2..3’’.. ®...
  • Page 36: Infrared (Ir) Remote

    Infrared (IR) Remote Any RJ45 Input IR Eye 12 V Trigger Tip DC +3V to +12V 50mA min Shielded 2 Conductor wiring Sleeve 18 Gauge or Larger 65ft (20 m) Max Supplied by installer ®...
  • Page 37 3rd Party Control System Hex Codes 0000 006c 0000 000c 0006 011b 0006 011b 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 011b 0006 08a4 0000 006c 0000 000c 0006 011b 0006 011b 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 011b 0006 011b 0006 08a4 0000 006c 0000 000c 0006 011b 0006 011b 0006 00bb 0006 00bb...
  • Page 38: Adjusting The Screen Tension

    Adjusting the Screen Tension 5 SERIES MOTORIZED ®...
  • Page 39 Adjusting the Screen Tension 5 SERIES MOTORIZED 0106165SM ®...
  • Page 40 Adjusting the Screen Tension 5 SERIES MOTORIZED Click..Click ..Click.. ®...
  • Page 41: Lifetime Replacement Policy

    To activate your Lifetime Replacement Policy, simply “Like” us on Facebook and/or “Follow” us on Twitter, and by all means, tell us about your SI experience! If you do not use Facebook or Twitter, you can submit your information online: www.screeninnovations.com/forms/lifetime-replacement-policy/...
  • Page 42: Troubleshooting

    Troubleshooting Problems related to electrical or motor function may require a qualified ser- vice person or electrician. Should you have a problem that is not addressed here, call: Screen Innovations (512-832-6939.) http://www.screeninnovations.com/category/support/ Problem Description Probably Cause Action to Take Motor shuts off. Motor has been Motor is designed for short Allow the motor to cool down.
  • Page 43 ® NOTES: 9715-B Burnet Road Suite 400, Austin,TX 78758 Tel: 512-832-6939 Fax: 512-832-6136 www.screeninnovations.com...