Summary of Contents for SI Solo 3 675 EXTERNAL INDOOR
Page 1
Solo 3 Indoor 675 External Installation Instructions INSTALLERS: PLEASE LEAVE THIS MANUAL WITH THE OWNER. Doc. #400202 | v. 1.0 | 25 January 2023...
Page 2
Scan the QR code to view the SI warranty for this product. Please use this QR Code to access the updated installation instructions and related documents. Technical Support: 512.832.6939 screeninnovations.com Hours of Support: 7:30am – 5pm CST screensupport@screeninnovations.com...
OPERATING AND CARE OF YOUR SCREEN • Operation of the screen systems should only be performed by responsible parties. • Always check the path of the Solo 3 Screen before operating to ensure that the path is clear of furniture or obstacles that could prevent full operation.
PARTS IN THE BOX – SOLO 3 675 EXTERNAL – INDOOR Screen Mounting Bracket Options (2/3) Ceiling Mount Brackets Case Assembly RJ45 Coupler Red Straps (AC – 485 screens only) (2/3) Wall Mount Brackets DUOCoup Required IR Remote RF Remote Hardware (1 per RTF screen) (for low voltage 485)
INSTALLATION METHODS Before installation, determine your installation method according to your product order and installation preferences. The indoor Solo 3 675 External may be installed preassembled or separately (fabric tube and material installed after the cassette). METHOD 1 – Assembled METHOD 2 –...
MOUNTING – BRACKETS BEFORE INSTALL– Check upper corners of the opening clearance, as necessary, to prevent interference with the cassette and end caps. Use appropriate fasteners to mount the ceiling brackets to structural supports. Mount brackets between (2–6’’) from the opening ends (additional brackets are intended to prevent cassette sag and should generally be applied to the middle of the cassette).
MOUNTING – CASSETTE Installation requires two or more people and/or hoisting equipment. Please use safe lifting and rigging techniques. For METHOD 1, lift and secure assembly onto brackets. Once the bracket engages, the cassette will “click” into place.
MOUNTING – THROUGH BOLTING CASSETTE NOTE: Be careful not to over-torque or aggressively drill retention hardware when mounting the cassette as deformation to the case could occur; this is especially important when ceiling mounting. The structure behind the mounting points should be flat and level. WARNING! Select a screw or anchor type that has a shallower head profile to eliminate the risk of contact with the screen material roll.
METHOD 1 INSTALLATION – UNPACKING Starting with the cassette secured onto the brackets, unscrew each end of the door (counterclockwise), then open the assembly to access the inside.
METHOD 1 INSTALLATION – WEIGHT BAR Remove both of the exposed red weight bar clips (2) by removing the attached screws from the bracket.
Page 12
METHOD 1 INSTALLATION – WEIGHT BAR Next, remove the screw attached to the weight bar from the red weight bar clips. Attach the magnetic endcap to the weight bar.
METHOD 1 INSTALLATION – FASCIA DOOR To secure the fascia door, set the door into the cassette; the door will hook in by gravity, as seen in the images below. Secure with screws.
METHOD 2 INSTALLATION – UNPACKING NOTE: The following section of the Solo 3 Indoor 675 External instructions applies to separately assembled projects where the cassette is installed prior to the fabric tube and material. Starting with the cassette on a soft, clean surface, remove the screws from the fascia door and open to reveal the inside.
METHOD 2 – MATERIAL ROLL REMOVAL Using the red straps, loop the straps under the material roll, being careful to avoid the material and any obstructions. With the help of the straps on both the ends, slowly pull out material roll and set it aside.
Page 16
METHOD 2 – MATERIAL ROLL REMOVAL Undo the silver safety screws, then press the latch as shown. Using the red straps, loop the straps under the material roll, being careful to avoid contact with the material or any obstructions. With the help of the straps on both the ends, slowly pull out material roll and set it aside.
METHOD 2 – MOUNTING CASSETTE Installation requires two or more people and/or hoisting equipment. Please use safe lifting and rigging techniques. Lift and secure the cassette onto the brackets. Once the bracket engages, the cassette will “click” into place.
METHOD 2 – MATERIAL ROLL REINSERTION With the cassette mounted, open the door and slide the material roll with mounting plates on each end into the cassette. Each end will “click” into place as the brackets engage. NOTE: The roll must remain level while installing into the cassette. Fasten the silver safety screws on the mounting plates to secure the material roll.
INSTALLATION – CEILING MOUNT – MOAB Push cassette all the way to the flanges and ceiling; fine tune as needed with a mounting key. Plug the motor power cable into the barrel connector (AC power), located within the cassette, or the terminal blocks (DC power) to connect Moab (see pages 5 - 7 for power options).
24v DC Power Supply From motor RS485 Data+ RS485 Data- RS485 Ground Scan this QR code to determine the max. length of the wire of the wiring on the three (3) options as shown below, or alternatively use this link: https://si-website-files.s3.amazonaws.com/Downloads/Programming+Guides/Shade/ wire-topologies.pdf...
INSIDE CASSETTE WIRING – 110V/220V AC 1. Terminate the wires with the provided terminal block, as shown below. 2. Locate junction box appropriately. Installer must follow all local electrical codes when connecting 110v AC power. Certified electrician is required to connect pigtail power. To 110v AC To head end/equipment To 110v AC...
COMMISSIONING GUIDE REFERENCE Moab Quick Start Guide (contains 485 instructions only): Scan the QR code, alternately use the link below to access https://files.screeninnovations.com/Downloads/Installation+Instructions/Connectivity/ moab-quick-start-guide.pdf Note: to get more detailed instructions refer to the Moab installation instructions below. Moab Installation Instructions (contains 485 detailed instructions): Scan the QR code, alternately use the link below to access https://files.screeninnovations.com/Downloads/Installation+Instructions/Connectivity/ moab-installation-instructions.pdf...
Page 24
Screen Innovations 9715-B Burnet Rd, Suite 400 Austin, TX 78758 512.832.6939 www.screeninnovations.com Doc. #400202 | v. 1.0 | 25 January 2023...