Toshiba RAV-SP1100UT-E Service Manual page 98

Hide thumbs Also See for RAV-SP1100UT-E:
Table of Contents

Advertisement

No.
Part name
Š
1. Detachment
Fan guard
1) Perform works of items
2) Remove the air flow cabinet, and put it
3) Take off screws fixing the bell mouth.
4) Remove the bell mouth.
5) Remove the hooking claws by pushing
2. Attachment
1) Insert claw of the fan guard in hole of the
2) Mount the bell mouth by hooking three
3) After attachment, fix the bell mouth with
Procedure
down so that the fan guard side directs
downward.
Perform work on a corrugated card-
board, cloth,etc. to prevent flaw to the
product.
(ST1Tf4 x 10L, 2 pcs.)
with minus screwdriver along with the
arrow mark as shown in right figure.
discharge panel. Push the hooking claws
(5 positions) with hands and fix the claws.
After all the attachment works are
completed, check that all the hooking
claws are fixed to the specified posi-
tions.
claws at upper side of the bell mouth in the
slits on the discharge cabinet.
screws. (ST1Tf4 x 10L, 2 pcs.)

to
.
98
Remarks
Minus screwdriver
Hooking claw
Discharge port cabinet
Slit (3 positions)
Bell mouth
Claw (3 positions)
Discharge
port cabinet
Bell mouth
Remove
two screws
Bell mouth
Discharge
port cabinet
Fan guard