  • Page 1 Home Integrated System Wireless Security & Home Automation System Installation & Operating Manual...
  • Page 2: Table Of Contents

    CONTENTS KIT CONTENTS Testing the Wall Switch INTRODUCTION AND OVERVIEW EXTERNAL CONNECTIONS Multiple Users System Arming TESTING THE SYSTEM Zones Initial Testing Entry/Exit Delay Testing an Installed System Quick Set Walk Test Zone Lockout RF Environment Test Event Log Digital Dialer Test Chime Voice Dialer Test Voice Dialer...
  • Page 3: Kit Contents

    KIT CONTENTS The Alarm System should contain the following components. For HIS20S 1 x Smart Home Box 1 x Wireless Key 1 x PIR Detector 1 x Remote Control 1 x Magnet Contact Detector 1 x On/Off Receiver...
  • Page 4: Introduction And Overview

    INTRODUCTION AND OVERVIEW ZONES MULTIPLE USERS The system incorporates 32 wireless Alarm Zones for The system allows for up to 7 Users and an the connection of the system detectors that are used to Administrator to be configured. This allows the independently monitor different areas of the property.
  • Page 5: Quick Set

    QUICK SET DIGITAL DIALER The system may be fully armed in 5 seconds using the As an alternative to the Voice dialer the system may be quick set facility, overriding the programmed exit-delay. configured to interface with a central monitoring station. This is useful for setting the system at night when the LATCH KEY exit-delay warning beep will be silenced after just a few...
  • Page 6: Battery Monitoring

    DISTANCE CONTROL & FEEDBACK a 5 minute interval, this will also generate a Full Alarm condition. You can achieve the controlling function of enhanced devices (i.e. devices with 868MHz radio frequency) via The jamming detection features in the Smart Home Box GSM Gateway or IP Gateway if they are enabled.
  • Page 7: Planning And Extending Your Wirefree Alarm System

    PLANNING AND EXTENDING YOUR Home Box, PIR, Magnetic Contact Detectors and Wall WIREFREE ALARM SYSTEM Switch for optimum security and home automation. You can use this as a guideline for planning your The following example shows a typical property intruder alarm and home automation system. incorporating the suggested positions for the Smart Smart Home...
  • Page 8: Remote Control Unit

    REMOTE CONTROL UNIT 4. In order to communicate with the Smart Home Box, the ID code of the Remote Control needs to be learned by the Smart Home Box. a. Set the Smart Home Box into ‘1. User Setup’ and press b.
  • Page 9: Mounting The Smart Home Box

    connecting to a telephone master or secondary Battery 1 (upper): Blue lead to +ve battery terminal outlet. Black lead to –ve battery terminal 7. Do not locate the Smart Home Box closer than 1m to any large metallic object, (e.g. mirrors, radiators, Battery 2 (lower): Red lead to +ve battery terminal etc) as this may affect the radio range of the Smart Blue lead to –ve battery terminal...
  • Page 10: Testing Smart Home Box & Remote Control

    Keyhole Slot Keyhole Slot -ve Terminal +ve Terminal (Black Lead) (Blue Lead) Terminal Block Hardwire Siren Tamper Return Link P51 +ve Terminal (Red Lead) Reset Jumper Link P1 -ve Terminal (Blue Lead) Power Supply Jack Socket Inside View of Smart Home Box TESTING THE SMART HOME BOX &...
  • Page 11: Choosing A Mounting Location

    When considering and deciding upon the mounting The PIR Detector adopts a 1/2 AA size 3.6V Lithium position for the detector the following points should be battery which under normal conditions will have typical considered to ensure trouble free operation: life in excess of 4 years.
  • Page 12: Setting The Pir Detectors

    2. Carefully drill out the required mounting holes in 7. To refit the PIR detector to the rear cover and the rear cover using 3mm drill according to whether locate the clips in the top edge into the rear cover. the unit is being mounted in a corner or against a Push the lower edge of the detector into place and flat wall.
  • Page 13: Testing The Pir Detectors

    Set the required sensitivity detection using DIP2 of the Smart Home Box. To proceed with ID code SW2 as follows: learning. high sensitivity detection a. Set the Smart Home Box into ‘3. Security low sensitivity detection Sensor Zone’ and press b.
  • Page 14: Magnetic Contact Detectors

    1. Press magnetic field, trigger the Detector and generate an alarm condition, (if the system is armed and the alarm zone active). to put the system into Test mode. ‘WALK TEST’ will be displayed. The Detector is powered by one 3.6V 1/2 AA size Lithium cells which under normal conditions will have 2.
  • Page 15: Setting The Magnetic Contact Detectors

    2. Fit the 3.6V Lithium battery supplied, with the negative (-) towards the battery spring. 3. Mount the Detector to the fixed part of the frame along the opening edge opposite the hinges using either the double sided adhesive tape or screws provided.
  • Page 16: Testing The Magnetic Contact Detectors

    b. Select ‘3-1 Wireless Sensor Zone’ and to put the system into Test mode. press ‘WALK TEST’ will be displayed. c. ‘Input (01-32) Sensor Zone’ and press d. An indication of ‘:1 Learning ID’ will be shown 2. Press to activate Walk Test. and press ‘...
  • Page 17: Learning Id Code

    status of the plug-in light fixtures or home appliances without controlling via Smart Home Box. LEARNING ID CODE In order to communicate with the Smart Home Box, the Smart Home Box will send ID code to the receiver. To proceed with ID code learning: On/Off Knob 2.
  • Page 18: External Connections

    1. Press to put the system into Test mode. ‘WALK TEST’ will be displayed. 2. Press to activate Walk Test. ‘ Walk Test Waiting…’ will be displayed. 3. By pressing ON or OFF knob each time, the Smart Home box will chime in response. EXTERNAL CONNECTIONS The Smart Home Box incorporates a terminal block for connection of hard-wired Zones (33-36), Siren or...
  • Page 19: Testing The System

    TESTING THE SYSTEM INITIAL TESTING Press As the system is initially installed it is recommended User Password that each device is tested in turn as it is installed, (refer to testing instructions for particular device). This puts the system into Test Mode. TESTING AN INSTALLED SYSTEM Use the buttons to scroll through...
  • Page 20: Rf Environment Test

    Press to exit Walk Test and return to the top press level Test Mode menu. This offers the flexibility of removing or changing siren’s RF ENVIRONMENT TEST battery. Wait for 10 seconds until ON/OFF duration has elapsed, then go ahead with fixing the siren as Scroll through the top level Test Mode menu until ‘...
  • Page 21 Night Alarm Double Call Time Key Tone Back Light Dial Method Setup Error Beep Dial Method DTMF Auto Report Function RF Jamming Detection Notification Setup Alarm Relay On Until Disarm Set Telephone Number Zone Lock Input Text Not Programmed Exit Delay Input Number Not Programmed Exit Delay Beep...
  • Page 22: Reset

    Backup & Restore 9. Close the Smart Home Box cover and refit the Backup Today’s DD/MM/YY fixing screws. Restore Not Programmed Note: please always remember the next step you RESET should carry out after resetting the Smart Home Box is ID code learning for each device.
  • Page 23: Programming Instructions

    PROGRAMMING INSTRUCTIONS Note: Programming is only available under Disarm With the system in Disarm Mode. Mode. While you are using the PC to do the program setting, the keypad on the Smart Home Box will Press become inactive unless you press for 3 seconds.
  • Page 24 LATCHKEY REPORT display once the system is armed/disarmed by the It is useful for a parent at work who wants to be sure particular user. The maximum memorized capacity for that his children have returned from school and have each user name is 15 digits. disarmed the system.
  • Page 25 Code Learning Scroll through the menu until ‘:7-4 Del data’ is Pressing button on the remote displayed. control will enable the Smart Home Box to learn the ID code. To change the setting press Scroll through the menu until ‘:7-1 Learning ID’ is Press to delete the remote control setting, or displayed.
  • Page 26: Home Box Setup

    HOME BOX SETUP PROGRAM MODE Code: 2. Home Box Setup 2-1 Alarm Time 2-3 EXT. Siren 2-4 Key Tone 2-5 Back Light 2-6 Error Beep xxx Sec. xxx SEC. xx SEC. :3-1 Wire Siren :3-2 Wirefree Siren :3-3 Night Alarm Select 10SEC 5SEC...
  • Page 27 Scroll through the top level programming menu until ‘2. To change the setting press HOME BOX SETUP’ is displayed and press Press to enable the Hardwired Siren, or Note: After completing the system setup press Press to disable the Hardwired Siren. to return to the top level programming menu.
  • Page 28 KEY TONE Scroll through the menu until ‘2-6 Error Beep’ is This feature, if enabled, allows the Smart Home Box to displayed. The current setting will also be displayed. sound a tone each time the keypad is pressed. To change the setting press Default setting: ON Scroll through available options, (10SEC, 30SEC, Scroll through the menu until ‘2-4 Key Tone’...
  • Page 29 ALARM RELAY Press to save and exit, or This setting controls the operation period for the Press to exit without saving. NO/NC hardwired output relay contacts following an alarm condition being initiated. EXIT DELAY BEEP If this is set to ‘ON Until Disarm’ then the relay will This controls the warning beep which operates during latch and remain On until the system is next disarmed.
  • Page 30 ID Duplicate – the same ID code was learned by the Press to enable the Entry-delay beep, or Smart Home Box beforehand. Press to disable the Entry-delay beep. DATE Keypad Off This feature is for setting of local date. Scroll through the menu until ‘:2 Keypad Work: xxx’ is Default setting: 1/1/2011 Sat displayed and press Scroll through the menu until ‘2-15 Date’...
  • Page 31: Security Sensor Zone Setup

    SECURITY SENSOR ZONE SETUP PROGRAM MODE Code: 3. Security Sensor Zone 3-1 Wireless 3-2 Wire Sensor Sensor Zone Zone Input (01-32) Input (33-36) Sensor Zone Sensor Zone :1 Wire Zone :1 Learning ID :2 Location :3 Model Type :4 Security Type :7 Partial Arm :5 Chime Mode :6 Night Arm...
  • Page 32 This section is for setting of adding and categorizing of Scroll through available options until the required security devices (e.g. PIR detector). Scroll through setting is displayed. the programming menu until ‘3. SECURITY SENSOR ZONE’ is displayed and press Press to save and exit, or Press to exit without saving.
  • Page 33 used to provide 24-hour monitoring of any NIGHT ARM Fire/Smoke detectors fitted system. This facility controls whether the sensor zone is active Activation of any detector will immediately initiate a when the system is set to night arm. Full Alarm condition. Default setting: OFF Panic/PA Scroll through the menu until ‘:6 Night Arm’...
  • Page 34 Press to disable the Magnetic Contact Press to keep the latest setting without Detector. changing. AUTO REPORT SIREN AT TRIGGER This feature, if enabled, allows the detector to give This decides whether the Smart Home Box will sound feedback to the Smart Home Box periodically with its or become silent when the sensor is triggered.
  • Page 35: Phone/Line Setup

    PHONE/LINE SETUP PROGRAM MODE Code: 4. Phone/Line 4-1 Voice Dial Setup :2 Record Voice :1 Voice Dial :2-1 :2-2 :2-3 Select :2-4 Intruder Main Message On> Off-> Fire Panic/PA Select Select Select Select Start-> Stop-> Start-> Stop-> Start-> Stop-> Start-> Stop->...
  • Page 36 required message type is displayed. Scroll through the programming menu until ‘4-1. Voice Dial Setup’ is displayed and press a) Main + Intruder Messages b) Main + Fire Messages Note: After completing the Phone/Line Setup press c) Main + Panic/PA Messages to return to the top level programming menu.
  • Page 37 Enter the required number (1-5). Press to delete the character under the cursor. Press to save and exit, or Press and hold to erase the entire phone Press to exit without saving. number. ARM/DISARM BY USER UNIT ID NUMBER This determines when user makes a selection for This helps central monitoring station set an ID number disarming (Open) or arming (Close) the system, an for the user whose system is connected to their center.
  • Page 38 Flow Chart for Control Call Routing Sequence (Monitor Center) Hang up Timeout Wait to enter ‘ ’ Begin 30 seconds the phone 30 Sec Event Trigger ‘ ’ KEY = Dial Preset Wait to enter TEL No. KEY, 5 Sec Send trigger message to monitor center...
  • Page 39 Enter the required number of ring (2-9). NUMBER OF DIALING CALL This facility controls the number of dialing call via the connected telephone line. Press to save and exit, or Press to exit without saving. Default setting: one call INTERVAL OF RING FOR DOUBLE CALL Scroll through the manual until ‘:1 Remote Type’...
  • Page 40: Notification Setup

    NOTIFICATION SETUP PROGRAM MODE Code: 5. Notification Setup 5-1 Set TEL No. :1-1 TEL 01 TEL2 TEL3 TEL4 TEL5 TEL6 TEL7 TEL8 TEL9 TEL10 Input Text Input Number Delete Level Panic Level 1 Level 2 5-2 TEL Confirm 5-4 Play Time 5-3 Dial Round 5-5 Call Abort xxx Sec...
  • Page 41 NOTIFICATION SETUP Press to enable the function of dialing and Scroll through the programming menu until ‘5. sending SMS, or Notification Setup’ is displayed and press Press to disable the function of dialing and Note: After completing the Notification Setup press sending SMS.
  • Page 42 To change the setting press Enter the required number (1-6). Press to enable Call Abort, or Press to disable Call Abort. Press to save and exit, or Press to exit without saving. Event Trigger DIAL ROUND This sets the maximum number of times that the dialer Dial Preset will attempt to contact each enabled telephone number TEL No.
  • Page 43: Green Home Setup

    GREEN HOME SETUP PROGRAM MODE Code: 6. Green Home 6-2 Green 6-1 Green Remote/Sensor Control Input (1-32) Input (1-32) Device Number Cont. Number :3 Device :1 Link Panel :2 Device :3 All ON :5 Model Type :7 Control Delete :1 Learning ID Delete to Control Status: xxx...
  • Page 44 Green Home setting is designed specially for home Default setting: off automation types of devices, i.e. device with 433 MHz radio frequency. Scroll through level To change the setting press programming menu until ‘6. GREEN HOME’ is displayed and press Press to enable the devices, or Note: To return to top level programming menu, press...
  • Page 45 Code Learning Scroll through available options, (Curtain Switch, Dimmer and Switch Device ) until the required model This enables the Smart Home Box learns ID from type is displayed and then Green Remote/Sensor. Press to save and exit, or Scroll through the menu until ‘:1 Learning ID’ is Press to exit without saving.
  • Page 46 Press to retain the device. RECORD SCENE VOICE This voice record is set for scene, event and schedule. Scroll through the menu until ‘6-3 Record Scene Voice’ is displayed and press Scroll through the menu until the required number of voice to be recorded is displayed and press Press to start recording or...
  • Page 47: Enhance Setup

    ENHANCE SETUP PROGRAM MODE Code: 7. Enhance 7-2 GSM Gateway 7-1 Enhance SMS Remote: xxx Device Input (01-12) Select E Device NO. ON-> OFF-> :1 Model Type :3 Device :2 Learning ID :4 Device Reset xxxx Status : xxx Select Learning…...
  • Page 48 Enhance setting is designed specially for transceiver Press to enable the device, or type of devices, i.e. device with 868 MHz radio Press to disable the device. frequency. Note: ON implies enable whereas OFF implies disable. Scroll through the top level programming menu until ‘7. The default setting will change to ON automatically Enhance Device’...
  • Page 49: Backup & Restore

    BACKUP & RESTORE Program Mode Code 8. Backup & Restore 8-1 Backup 8-2 Restore DD/MM/YY DD/MM/YY Select Select YES-> NO-> YES-> NO-> Scroll through the programming menu until ‘8. BACKUP & RESTORE’ is displayed and press Use the buttons to scroll through the menu until the required option is displayed and press BACKUP...
  • Page 50: Operating Instructions

    OPERATING INSTRUCTIONS Press the ‘Arm’ button, When leaving the premises, the system must be Armed. Smart Home Box: However, before doing so, check that all windows are Press the ‘Arm’ button followed by the User Password closed and locked, all protected doors are closed and and then the ‘Enter’...
  • Page 51: Partial Arm

    Password, and then the ‘Enter’ button. If User system disarmed ‘ALARM password is correct, an indication of ‘Night Arm’ will be MEM/MESSAGE’ LED is flashing with the panel shown on the LCD screen: beeping every few seconds, this indicates that an alarm condition has occurred.
  • Page 52: Led Indication

    LED INDICATION (On), (Off), (Start) and (Stop) buttons to control the green control related actions. The LED indication represents the following status: Scene On steadily Flash ----- AC power in use Battery in use Press to enter scene selection function, and System is System is set in System is...
  • Page 53: Telephone Line Detection

    Setting Sequence: with the central monitoring station for help. REMOTE SYSTEM CONTROL Press -> plays “I will watch over the house!” -> system enters fully arm mode -> PIR Detector sets to If the Remote System Control facility is enabled, the ON while Magnet Contact Detector and Green Control Smart Home Box will answer the call after the set sets to OFF.
  • Page 54: Battery Monitoring

    normal operation (under Disarm mode). However, the battery for that device should be replaced as soon as Press to initiate ARM. possible. Press to initiate Partial Arm. Note: Before removing the battery cover on any device to replace the battery ensure that the system is put into Press to initiate Holiday Arm.
  • Page 55: Maintenance

    removed). Remote Controls 1 x 3V CR2032 Lithium Cells (or equivalent) Wall Switch Magnetic Contact 1 x 3.6V 1/2 AA Size Lithium Under low battery conditions, when the button is Detectors Cells (or equivalent) pressed, the LED will flash. PIR Detectors 1 x 3.6V 1/2 AA Size Lithium Cells (or equivalent) Under normal battery conditions the LED will illuminate...
  • Page 56: Alarm Record

    ALARM RECORD Complete the following information during installation for future reference when adding to your system and to assist Trouble Shooting. Security Sensor Zone Settings Zone Detector Location Type Chime Night Arm Partial Arm Type(s)
  • Page 57 Zone Detector Location Type Chime Night Arm Partial Arm Type(s) You may make a note of your User Password and Installer Password below. System Password User 1: _______________________ User 2: _______________________ User 3: _______________________ User 4: _______________________ User 5: _______________________ User 6: _______________________ User 7: _______________________ Admin.
  • Page 58: Alarm Level

    ALARM LEVEL To help you distinguish the difference among Level Panic, Level 1, Level 2 and Level 3, their definition read as follows: Level Panic: Alarm + Voice Dialer + SMS for GSM Gateway + Error Beep + Event Log When the Smart Home Box is triggered (fire, panic, intruder and 24h intruder) in the event of fire incident, an alarm will occur, the built-in voice Dialer will dial the preset phone number, GSM gateway will send SMS message, error beep will generate at regular intervals after alarm duration has expired and this specific event will be recorded in the...
  • Page 59 Gateway will send SMS message, error beep will generate at regular intervals and this specific event will be recorded in the event log as well. Level 3: Event Log When the Smart Home Box is armed or disarmed, this specific event will be recorded in the event log.
  • Page 60: Troubleshooting

    TROUBLESHOOTING Smart Home Box not working – Power LED OFF Smart Home contacting central or flashing monitoring station service on alarm 1. Mains power failure – check if other electrical 1. Telephone line not connected or faulty – check circuits are operable. phone line with another phone.
  • Page 61: Digital Dialer Transmission

    Magnetic Contact Detector not working LED on remote control not illuminating, or is 1. Ensure batteries are connected with correct dim when unit is operated polarity. 1. Ensure battery is connected with correct polarity 2. Ensure battery connections are good. 2.