Sony HVR-Z5C Service Manual page 285

Digital hd video camera recorder
Hide thumbs Also See for HVR-Z5C:
Table of Contents

Advertisement

4. COMPONENT OUT Pb Level Adjustment
(VC-543 board)
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
1
0
01
2
7
83
3
3
71
4
0
10
8
5
5C
(18)
8
6
5D
(18)
7
0
10
8
C
8D
9
C
8D
10
11
0
10
8
12
5C
(18)
8
13
5D
(18)
14
0
10
15
3
70
16
3
70
17
7
83
18
0
01
Note: For the bit values, refer to "6-4. SERVICE MODE", "4-4.
3. Bit value discrimination".
B
C
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
CAMERA mode
Arbitrary
P
/C
signal terminal of COMPO-
b
b
NENT OUT plug of A/V Remote
connector (75 Ω terminated)
Oscilloscope
C
8D
Pb level: A = 525 ± 10 mVp-p
Sync level: B = C = 300 ± 10 mVp-p
Procedure
01
02
01
Press PAUSE (Write) button.
01
Set the bit value of bit0 is
"1", and press PAUSE
(Write) button. (Note)
05
Press PAUSE (Write) button.
00
Change the data and set the
Pb signal level (A) to the
specified value.
Press PAUSE (Write) button.
Check the sync signal (B, C)
to the specified value.
01
Set the bit value of bit0 is
"0", and press PAUSE
(Write) button. (Note)
00
Press PAUSE (Write) button.
00
10
Press PAUSE (Write) button.
Check the data changes to
"11".
00
00
H
Fig. 6-3-8
A
6-109

Advertisement

Table of Contents
loading

Table of Contents