Sony HVR-Z5C Service Manual page 279

Digital hd video camera recorder
Hide thumbs Also See for HVR-Z5C:
Table of Contents

Advertisement

4.
SD Error Rate Check (VC-543 board)
Note: Check that the data of page: 0, address: 10 is "00".
4-1. Preparations before adjustments
Mode
Camera recording (CAMERA mode)
Subject
Arbitrary
Switch setting
1) REC FORMAT (Menu setting) ......................................... DV
Adjusting method:
Order Page Address Data
1
0
01
2
3
71
3
0
10
C
4
0D
(1C)
5
0
10
6
3
1D
7
4-2. Error Rate Check
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Initial Value of Page C: Address: B2 to C7
Initial
Address
Address
value
B2
00
B3
00
B4
00
B5
00
B6
00
B7
80
B8
00
B9
00
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
RadarW
RadarW
RadarW
RadarW
RadarW
Procedure
01
01
Press PAUSE (Write) button.
01
CC
Press PAUSE (Write) button.
00
20
Press PAUSE (Write) button.
Record the camera signal for
2 minutes.
VTR playback (VCR mode)
Recorded signal at "Preparations
before adjustments"
Displayed data of page: 3, address:
03
Adjusting remote commander
C
B2 to C7
The data of page: 3, address: 03 is
"00"
Initial
Address
value
BA
00
C2
BB
00
C3
BC
00
C4
BD
00
C5
BE
00
C6
BF
00
C7
C0
00
C1
00
Table 6-3-4
Adjusting method:
Order Page Address Data
1
0
2
3
3
4
5
3
6
3
7
3
8
3
9
3
10
Note 2: If the data is other than "00", Error rate is abnormal.
For the contents of the abnormality, see the following
table.
Data of page: 3,
address: 03
01
02
03
Note 3: If Error rate is abnormal, Check the use tape, clean the
tape running surface. And after inputting initial values to
page C: address: B2 to C7, perform re-adjustment. (See
Table 6-3-4)
Processing after Completing Adjustment:
Order Page Address Data
1
0
2
0
Initial
C
value
3
(1C)
80
4
0
00
5
3
00
6
3
00
00
7
0
00
6-103
Procedure
01
01
71
01
Press PAUSE (Write) button.
Check that the data of page:
C, address: B2 to C7 is the
initial value. (See Table 6-3-
4)
Playback the recorded signal
at "Preparations before
adjustments".
03
FF
Press PAUSE (Write) button.
01
40
Press PAUSE (Write) button.
Check the data changes to
02
"00".
03
Check the data is "00". (Note 2)
01
00
Press PAUSE (Write) button.
Perform "Processing after
Completing Adjustments".
Contents of defect
EVEN channel is abnormal.
ODD channel is abnormal.
EVEN channel and ODD channel are
abnormal.
Procedure
01
01
10
01
0D
00
Press PAUSE (Write) button.
10
00
70
10
Press PAUSE (Write) button.
Check the data changes to
70
"11".
01
00

Advertisement

Table of Contents
loading

Table of Contents