7. Flange Back Adjustment
(Using the minipattern box or flange back adjustment
jig)
[Preparation (Using the minipattern box)]
1) The minipattern box is installed as shown in the following fig-
ure.
Note: The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage ± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Output voltage : Specified voltage ± 0.01 Vdc
Output current : more than 3.5 A
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
[Preparation (Using the flange back adjustment jig)]
(Illuminance: 550 to 650 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Flange back adjustment jig
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Below 3 cm
Camera
Regulated power supply
Need not connected
Fig. 6-1-6
Below 3 cm
Camera
Fig. 6-1-7
7-1. Flange Back Adjustment
(Using the minipattern box or flange back adjust-
ment jig)
Perform the flange back adjustment. In whichever case, the focus
will be deviated during auto focusing/manual focusing.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Dark Siemens star chart.
Note 2: Perform "PSD Sensor Gradient Adjustment", "Lens Ad-
justment", "Zoom Ring Adjustment", "Focus Ring Ad-
justment" after this adjustment.
Note 3: Perform the adjustment with the lens in horizontal state.
Note 4: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 5: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: Don't touch the zoom ring during adjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
6-27
RadarW
RadarW
RadarW
Siemens star chart for minipattern
box (Note 1) or flange back
adjustment jig
Adjusting remote commander
6F
20 to 3F
Data of page: 06, address: 0C is "00"