26. Auto White Balance Standard Data Input
(ND3)
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "Linear Matrix Adjustment" and "Auto White
Balance Standard Data Input" before this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 3: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
1
0
01
2
6
99
3
6
02
4
6
07
5
6
40
6
6
41
7
6
13
8
6
01
9
6
02
10
6
0C
Note 4: The adjustment data will be automatically input to page:
6F, address: 94 to 97.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
40
3
6
41
4
6
13
5
0
01
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Clear chart (Color reproduction
adjustment frame)
Adjusting remote commander
6F
94 to 97
Data of page: 6 address: 0C is "00"
Procedure
01
Check the data is "03".
Check the data is "00".
Check the data is "04"."
01
01
BF
Press PAUSE (Write) button.
0B
(Note 4)
Check the data changes to
"01".
Check the data is "00".
Procedure
00
Press PAUSE (Write) button.
00
00
00
00
27. Auto White Balance Adjustment (ND3)
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Filter
Adjustment Page
Adjustment Address
Note 1: Perform "Linear Matrix Adjustment" and "Auto White
Balance Adjustment" before this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 3: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
1
2
0
01
3
6
99
4
6
02
5
6
07
6
6
40
7
6
41
8
6
13
9
6
01
10
6
02
Note 4: The adjustment data will be automatically input to page:
6F, address: A4 to A7.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
40
3
6
41
4
6
13
5
0
01
6
6-41
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart
(Color reproduction adjustment
frame)
Filter C14 for color temperature
correction
6F
A4 to A7
Procedure
Place the C14 filter on the
lens.
01
Check the data is "03".
Check the data is "00".
Check the data is "04".
01
01
BD
Press PAUSE (Write) button.
81
(Note 4)
Check the data changes to
"01".
Procedure
00
Press PAUSE (Write) button.
00
00
00
00
Remove the C14 filter on the
lens.

Advertisement

Table of Contents
loading

Table of Contents