28. Auto White Balance Check (ND3)
Subject
Filter
Measurement Point
Measuring Instrument
Specified Value
Note 1: Perform "Auto White Balance Standard Data Input
(ND3)", "LV Standard Data Input" and "Auto White Bal-
ance Adjustment (ND3)" before this adjustment.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
1
0
01
2
6
9B
3
6
99
4
6
07
5
6
40
6
6
41
7
6
CA
8
6
C9
9
6
13
OUTDOOR white balance check
10
6
01
11
6
02
12
6
0C
13
6
01
INDOOR white balance check
14
6
01
15
6
02
16
6
0C
17
6
01
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart (Color reproduction
adjustment frame)
ND filter 1.0, 0.4 and 0.1
Adjusting remote commander
Data of page: 6, address: 0C is "00"
Procedure
01
Check the bit value of bit2 is
"0". (Note 3)
Check the data is "03".
Check the data is "04".
01
01
85
10
BF
4F
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
0F
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
Order Page Address Data
InOut check
18
19
6
C9
20
6
13
21
22
6
01
23
6
02
24
6
0C
25
6
01
26
Note 3: For the bit values, refer to "6-4. SERVICE MODE", "4-
4. 3. Bit value discrimination".
Processing after Completing Adjustment:
Order Page Address Data
1
6
C9
2
6
CA
3
6
40
4
6
41
5
6
13
6
0
01
6-42
Procedure
Place the ND filter 1.5 (1.0
+0.4 + 0.1) on the lens.
11
BE
Wait for 3 seconds.
4B
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Procedure
00
00
00
00
00
00