Sony HVR-Z5C Service Manual page 194

Digital hd video camera recorder
Hide thumbs Also See for HVR-Z5C:
Table of Contents

Advertisement

1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of "VIDEO SYSTEM ADJUSTMENTS" are sat-
isfied. (Except Origin Oscillation Check")
Check that the data of page: 0, address: 10 is "00".
If not, select page: 0, address: 10, and set the data "00".
1-3-1.
Camera System Adjustments
1. Origin Oscillation Check (VC-543 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Measurement Point
Measuring Instrument
Specified value
Switch setting
1) POWER ......................................................... CAMERA mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
VC-543 BOARD (SIDE A)
IC1601
IC1401
R1414
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Not required
R1414 (CHCK) on VC-543 board
Frequency counter
f = 41538461 ± 835 Hz (NTSC)
f = 41580000 ± 835 Hz (PAL)
Fig. 6-1-5
2. Coaxial Harness Connecting Check
Check if the coaxial harness of CMOS is connected correctly.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Check that the data of page: 6, address: 02 is "00"
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
1
0
01
2
6
07
3
0
10
E
4
90
(9E)
E
5
80
(9E)
6
0
10
7
6
01
8
6
02
9
6
D0
Note 2: The adjustment data will be automatically input to page:
6, address: D1 to D6.
Note 3: For the error codes of bit 0 to bit 2 of data of page: 6,
address: D0, see the following table.
Bit value of data of
page: 6,
address: D0
Bit
Function
When bit value = 0 When bit value = 1
0
R
1
G
2
B
Example: If an error exists in G, data is "05"
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
10
E
3
90
(9E)
E
4
80
(9E)
5
0
10
6
0
01
6-24
RadarW
RadarW
RadarW
RadarW
RadarW
Not required
Adjusting remote commander
6
D1 to D6
Data of page: 6, address: D0 is "07"
Procedure
01
Check the data is "04".
09
10
00
00
Press PAUSE (Write)
EB
button.(Note 2)
Check the data changes to
"01".
Check the data is "07".
(Note 3)
Error contents
Error exists
No error
Error exists
No error
Error exists
No error
Procedure
00
Press PAUSE (Write) button.
09
00
70
00
00

Advertisement

Table of Contents
loading

Table of Contents