Electronic ignition self-test

The electronic ignition for the gas hob
carries out a self-test as soon as the
first burner is switched on or the last
burner is switched off. The self-test
lasts about 1.5 seconds. If the self-test
is interrupted, this is counted as a
failure by the electronics and the light
ring on the rotary control will flash. The
rotary control for the griddle plate is
also equipped with a light ring. This
light ring does not flash if the self-test
was interrupted.
The following situations can cause this
error:
– You switch on the first burner.
Immediately after switching on
(during the self-test) you switch the
burner off and another one on. The
self-test will be interrupted by this.
The light ring on the rotary control will
flash.
– You switch the last burner off.
Immediately after switching off you
switch a burner on again. The light
ring on the rotary control will flash.
However the gas supply is cut off and
a gas leak is prevented.
If the rotary control is turned clockwise
to the  position (Off), the burner is
ready for use again after approx.
1.5 seconds.
Special requirements HR 1956
The HR 1956 Range Cooker has two
independent ignition safety devices. If
the self-test is interrupted on one half of
the hob, the other half is not affected.
HR 1956
a Electronic ignition 1
for the burners on the left hand side,
including the griddle plate
b Electronic ignition 2
for the burners on the right hand
side