1336 PLUS™ Variable Frequency, 1336 PLUS™ II, 1336 FORCE - Vector Control, 1336 IMPACT Product Selection
Enclosure Options Available to All Units:
Option
Description
Section
(7)(12)
Depth
15" deep MCC (Y = option avail.)
20" deep MCC (Y = option avail.)
25" deep MCC (Y = option avail.)
1.5 Inch High
Required (R) or Optional (O):
Base
(5)(7)
Channels
Horizontal Power
(8)(13)(14)(15)
Bus
(16)
800A (Y = option avail.)
1200A (Y = option avail.)
1600A (Y = option avail.)
2000A (Y = option avail.)
3000A (Y = option avail.)
Ground Bus (PE/
PE/TE bus for unit with horizontal power bus rated up to 2000A
(9)(16)
TE)
PE/TE bus for unit with horizontal power bus rated up to 3000A
115V AC Control
90A control bus
(10)(16)
Bus
(17)
Top Hat
12" high top hat for extra entry cable bending radius
(1) You must select (1) option from this group.
(2) All drives mounted in the same MCC vertical section must have option 111 if any one drive unit has option 111.
(3) You may select up to (1) option from this group.
(4) Pilot lights are Allen-Bradley® Bulletin 800M products and the pushbutton is an Allen-Bradley Bulletin 800T device.
(5) If one drive unit has base channels in any lineup, the entire lineup must have base channels. Base channels add 1.5 inches to the unit height.
(6) Option 6P is not available for drive units with voltage codes D, S, E, and F.
(7) If you are connecting to an FD86N cabinet, you must select base channels and enclosures that are 20 inches and/or 25 inches deep.
(8) Units with voltage codes D, S, E and F require horizontal power bus options. Only 800A, 1600A, and 3000A are available.
(9) You must select a ground bus option. If your lineup has a 3000A power bus, you must select the ground bus option for units with a 3000A-rated power bus.
(10) You must select a horizontal power bus option if you select a control bus.
(11) Units come standard with cloth wire labels. Datab labels offer the added protection of a clear plastic cover on top of the labels.
(12) If at least one unit in a lineup is 20 inches or 25 inch deep flush back, then all other drive units in that lineup must be 20 inches or 25 inches deep.
(13) If the drive unit is mounted in a 25 inch deep flush front enclosure, you must select a 3000A horizontal power bus for that unit. If you have drives mounted in 15 inch or 20 inch deep sections
in the same lineup, you may select a different horizontal power bus option; but all non-25 inch deep enclosure units in a lineup must have the same horizontal power bus option. The
horizontal power bus rating of the entire lineup equals the lowest power bus rating selected.
(14) Horizontal power bus is braced for 65kAIC.
(15) Maximum of 120 inches per shipping split.
(16) Horizontal power bus and control bus (if selected) are mounted at a depth of 11.94 inches in all MCC sections containing frame A, B, and C drive units, regardless of section depth. Frame
D, E, F, G, and H drives units have power bus and control bus (if selected) mounted at a depth of 16.94 inches or greater with bus ends for splicing always at a depth of 16.94 inches. Select
offset splice kit(s) when shipping split requires splicing bus ends at a depth of 11.94 inches to bus ends at a depth of 16.94 inches. If both sections have bus ends at the same depth, select
straight splice kits. Use the tables in the Power Bus Splice Kit Catalog Numbers section on
(17) Frame F, G, and H drive units require top hats if input power is not supplied by a power bus option.
(18) Requires an expended cassette for Phase II control.
(19) Available for Phase II control only. Requires an expanded cassette.
(20) For dual communications (DPI and DriveLogix) select the DriveLogix comm. option and order the DPI comm. kit separately.
Input Voltage > 230V AC
380/460V AC
Frame Size >
Y
Y
Y
Y
O
O
Input Voltage > 230V AC
310V DC
380V AC
512V DC
460V AC
620V DC
575V AC
775V DC
Y
Y
Y
Y
Y
575V AC
310V DC
Y
Y
Y
Y
Y
Y
O
R
O
O
R
Y
Y
Y
page 4-1
to select splice splits per shipping split.
512V/620V DC
775V DC
Y
Y
Y
Y
Y
Y
Y
Y
O
O
O
R
O
2-5
Y
Y
O
R