6. SOUND PRESSURE LEVELS
Measurement condition
PQRY-P144, 168, 192, 216, 240TLMU-A/YLMU-A
Measurement
location
Sound level of PQRY-P144TLMU-A/YLMU-A
90
Stand 60Hz
Low
60Hz
80
70
60
50
40
30
Approximate minimum
20
audible limit on
continuous noise
10
63
125
250
500
Octave band central frequency (Hz)
63
125
250
Standard
60Hz
75.5 53.5 52.0 48.0 48.0
Low noise mode
60Hz
54.0 53.5 47.5 43.5 43.5
When Low noise mode is set,the A/C system's capacity is limited. The system could return to normal operation
from Low noise mode automatically in the case that the operation condition is severe.
Sound level of PQRY-P168TLMU-A/YLMU-A
90
Stand 60Hz
Low
60Hz
80
70
60
50
40
30
Approximate minimum
20
audible limit on
continuous noise
10
63
125
250
500
Octave band central frequency (Hz)
63
125
250
Standard
60Hz
48.0 50.0 57.5 46.5 48.5
Low noise mode
60Hz
66.5 45.5 46.5 44.0 46.0
When Low noise mode is set,the A/C system's capacity is limited. The system could return to normal operation
from Low noise mode automatically in the case that the operation condition is severe.
• •
Depending on the operation conditions, the unit generates noise caused by valve actuation, refrigerant flow, and pressure
changes when operating normally. Please consider to avoid location where quietness is required.
For BC controller, it is recommended to be installed in places such as ceilings of corridor, rest rooms and plant rooms.
© 2017 Mitsubishi Electric US, Inc.
Sound level of PQRY-P192TLMU-A/YLMU-A
3-1/4ft.
(1m)
Standard
Low noise mode
When Low noise mode is set,the A/C system's capacity is limited. The system could return to normal operation
from Low noise mode automatically in the case that the operation condition is severe.
Sound level of PQRY-P216TLMU-A/YLMU-A
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
1k
2k
4k
8k
500
1k
2k
4k
8k
dB(A)
43.5
40.5
33.5
54.0
Standard
42.0
44.5
40.5
50.5
Low noise mode
When Low noise mode is set,the A/C system's capacity is limited. The system could return to normal operation
from Low noise mode automatically in the case that the operation condition is severe.
Sound level of PQRY-P240TLMU-A/YLMU-A
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
1k
2k
4k
8k
500
1k
2k
4k
8k
dB(A)
47.5
50.0
43.0
56.0
Standard
42.0
45.0
40.5
51.5
Low noise mode
When Low noise mode is set,the A/C system's capacity is limited. The system could return to normal operation
from Low noise mode automatically in the case that the operation condition is severe.
PQRY-P-T(S)LMU, Y(S)LMU (April 2017 Ver2)
90
Stand 60Hz
Low
60Hz
80
70
60
50
40
30
Approximate minimum
20
audible limit on
continuous noise
10
63
125
250
500
1k
Octave band central frequency (Hz)
63
125
250
500
60Hz
53.5 59.0 54.0 54.0 50.5
60Hz
59.5 52.5 50.5 49.0 45.0
90
Stand 60Hz
Low
60Hz
80
70
60
50
40
30
Approximate minimum
20
audible limit on
continuous noise
10
63
125
250
500
1k
Octave band central frequency (Hz)
63
125
250
500
60Hz
47.0 69.5 52.0 54.5 50.0
60Hz
65.5 62.5 58.0 47.5 45.5
90
Stand 60Hz
Low
60Hz
80
70
60
50
40
30
Approximate minimum
20
audible limit on
continuous noise
10
63
125
250
500
1k
Octave band central frequency (Hz)
63
125
250
500
60Hz
47.0 61.0 61.0 53.0 49.5
60Hz
66.0 54.0 54.0 47.5 47.0
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
2k
4k
8k
1k
2k
4k
8k
dB(A)
47.0
52.0
49.0
58.0
45.0
49.5
40.0
54.0
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
2k
4k
8k
1k
2k
4k
8k
dB(A)
43.5
47.0
41.5
58.0
43.5
39.5
38.5
54.0
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
2k
4k
8k
1k
2k
4k
8k
dB(A)
47.0
49.0
44.5
58.0
48.5
43.0
39.5
54.0
WR2-47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents