Mitsubishi Electric PQRY-P72TLMU-A Manual page 25

Table of Contents

Advertisement

1. SPECIFICATIONS
Model
Power source
Cooling capacity (Nominal) *1 (460V)
Power input
Current input
Indoor
Temp. range of
cooling
Circulating water *3
(460V)
Heating capacity (Nominal) *2
Power input
Current input
Indoor
Temp. range of
heating
Circulating water *3
Total capacity
Indoor unit
connectable
Model / Quantity
Sound pressure level (measured in anechoic room)
High pressure
Refrigerant piping
diameter
Low pressure
Module Set
Module
External finish
External dimension HxWxD
Net weight
Type
Water volume in plate
Heat exchanger
Water pressure Max.
Type
Manufacturer
Compressor
Starting method
Motor output
Lubricant
Water flow rate
Circulating water *3
Pressure drop
Operating volume range
High pressure protection
Protection devices
Inverter circuit(comp)
Compressor
Minimum Circuit Ampacity(MCA)
Maximum Overcurrent Protection(MOP)
Type x original charge
Refrigerant
Control
High pressure
Pipe between unit
and distributor
Low pressure
External
Drawing
Wiring
Document
Standard
attachment
Accessory
Optional parts
Remarks
Note:
*1 Nominal cooling conditions (subject to JIS B8615-1)
Indoor:
81degF D.B./ 66degF W.B. (27degC D.B./ 19degC W.B.) 68degF D.B. (20degC D.B.)
Water Temp.:
86degF (30degC)
Pipe length:
24-9/16ft.(7.5m)
Level difference:
0ft.(0m)
* Due to continuing improvement, above specifications may be subject to change without notice.
© 2017 Mitsubishi Electric US, Inc.
Btu/h
kW
kW
A
W.B.
Btu/h
kW
kW
A
D.B.
P06~P96/2~50 (Connectable branch pipe number is max. 48.)
dB <A>
in.(mm)
in.(mm)
PQRY-P168YLMU-A
in.
57-1/8 x 34-11/16 x 21-11/16
mm
1,450 x 880 x 550
lbs(kg)
505 (229)
Plate
G
1.32
I
5
psi
290
MPa
2
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Inverter
kW
11.0
MEL32
G/h
G/min(gpm)
m
3
/ h
L/min
cfm
psi
6.38
kPa
44
G/h
G/min(gpm)
m
/ h
3
High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
A
20
A
35
R410A x 13 lbs + 4 oz (6.0 kg)
in.(mm)
7/8 (22.2) Brazed
in.(mm)
-
KE94C952
Joint: CMY-Y102SS-G2, CMY-Y102LS-G2, CMY-Y202S-G2, CMY-Y302S-G2, CMY-R160-J1
Main BC controller: CMB-P108, 1010, 1016NU-HA1
Sub BC controller: CMB-P104, 108NU-GB1, CMB-P1016NU-HB1
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
The ambient temperature of the Heat Source Unit needs to be kept below 104°F DB(40° C DB).
The ambient relative humidity of the Heat Source Unit needs to be kept below 80%.
The Heat Source Unit should not be installed at outdoor.
Mount a strainer (more than 50 meshes) at the water inlet piping of the unit.
The Heat Source twinning kit (low pressure) should be connected to the low pressure side of the
heat source unit.
A field provided flow switch is required for minimum flow protection on each module, field installed
and wired to TB8 (terminal 3-4).
*3 If using Circulating water temperatures that are between 23 and 50° F, Dip switch 3-9 must be
turned on and glycol must be used in the water loop to prevent freezing down to 5° F.
*2 Nominal heating conditions (subject to JIS B8615-1)
68degF (20degC)
25ft.(7.6m)
0ft.(0m)
PQRY-P-T(S)LMU, Y(S)LMU (April 2017 Ver2)
PQRY-P312YSLMU-A
3-phase 3-wire 460 ±10% 60Hz
312,000
91.4
23.41
32.6
59~75° F (15~24° C)
50~113° F (10~45° C)
350,000
102.6
19.11
26.6
59~81° F (15~27° C)
50~113° F (10~45° C)
50~150% of heat source unit capacity
58
1-1/8 (28.58) Brazed
1-3/8 (34.93) Brazed
PQRY-P144YLMU-A
Galvanized steel sheets
57-1/8 x 34-11/16 x 21-11/16
1,450 x 880 x 550
Inverter scroll hermetic compressor
1,902 + 1,902
31.7 + 31.7
7.20 + 7.20
120 + 120
4.2 + 4.2
1,189 + 1,189 ~ 3,054 + 3,054
19.8 + 19.8 ~ 50.9 + 50.9
4.5 + 4.5 ~ 11.6 + 11.6
Over-heat protection, Over-current protection
Over-heat protection
R410A x 13 lbs + 4 oz (6.0 kg)
Indoor LEV and BC controller
7/8 (22.2) Brazed
1-1/8 (28.58) Brazed
KJ94T154
Installation Manual
Details refer to External Drw
Heat Source Twinning kit: CMY-Q200CBK
Unit converter
BTU/h =kW x 3,412
cfm =m
3
/min x 35.31
lb =kg / 0.4536
* Above specification data is subject to rounding
variation.
505 (229)
Plate
1.32
5
290
2
Inverter
9.5
MEL32
6.38
44
16
25
KE94C952
WR2-25

Hide quick links: