Mitsubishi Electric PQRY-P72TLMU-A Manual page 23

Table of Contents

Advertisement

1. SPECIFICATIONS
Model
Power source
Cooling capacity (Nominal) *1 (460V)
Power input
Current input
Indoor
Temp. range of
cooling
Circulating water *3
(460V)
Heating capacity (Nominal) *2
Power input
Current input
Temp. range of
Indoor
heating
Circulating water *3
Total capacity
Indoor unit
connectable
Model / Quantity
Sound pressure level (measured in anechoic room) dB <A>
Refrigerant piping
High pressure
diameter
Low pressure
Module Set
Module
External finish
External dimension HxWxD
Net weight
Type
Water volume in plate
Heat exchanger
Water pressure Max.
Type
Manufacturer
Compressor
Starting method
Motor output
Lubricant
Water flow rate
Circulating water
*3
Pressure drop
Operating volume range
High pressure protection
Protection devices
Inverter circuit(comp)
Compressor
Minimum Circuit Ampacity(MCA)
Maximum Overcurrent Protection(MOP)
Type x original charge
Refrigerant
Control
Pipe between unit
High pressure
and distributor
Low pressure
External
Drawing
Wiring
Document
Standard
attachment
Accessory
Optional parts
Remarks
Note:
*1 Nominal cooling conditions (subject to JIS B8615-1)
Indoor:
81degF D.B./ 66degF W.B. (27degC D.B./ 19degC W.B.) 68degF D.B. (20degC D.B.)
Water Temp.:
86degF (30degC)
Pipe length:
24-9/16ft.(7.5m)
Level difference:
0ft.(0m)
* Due to continuing improvement, above specifications may be subject to change without notice.
© 2017 Mitsubishi Electric US, Inc.
Btu/h
kW
kW
A
W.B.
Btu/h
kW
kW
A
D.B.
P06~P96/2~50 (Connectable branch pipe number is max. 48.)
in.(mm)
7/8 (22.2) Brazed (1-1/8 (28.58) Brazed for the part that exceeds 65 m)
in.(mm)
PQRY-P120YLMU-A
in.
43-5/16 x 34-11/16 x 21-11/16
mm
1,100 x 880 x 550
lbs(kg)
404 (183)
Plate
G
1.32
I
5.0
psi
290
MPa
2.0
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Inverter
kW
7.7
MEL32
G/h
G/min(gpm)
m
/ h
3
L/min
cfm
psi
3.48
kPa
24
G/h
G/min(gpm)
m
/ h
3
High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
A
13
A
20
R410A x 11 lbs + 1 oz (5.0 kg)
in.(mm)
3/4 (19.05) Brazed
in.(mm)
-
KE94C952
Joint: CMY-Y102SS-G2, CMY-Y102LS-G2, CMY-Y202S-G2, CMY-Y302S-G2, CMY-R160-J1
Main BC controller: CMB-P108, 1010, 1013, 1016NU-GA1, 108, 1010, 1016NU-HA1
Sub BC controller: CMB-P104, 108NU-GB1, CMB-P1016NU-HB1
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other
items shall be referred to the Installation Manual.
The ambient temperature of the Heat Source Unit needs to be kept below 104°F DB(40° C DB). The
ambient relative humidity of the Heat Source Unit needs to be kept below 80%.
The Heat Source Unit should not be installed at outdoor. Mount a strainer (more than 50 meshes) at the
water inlet piping of the unit.The Heat Source twinning kit (low pressure) should be connected to the low
pressure side of the heat source unit. Install the supplied insulation material to the unused drain-socket.
When installing insulation material around both water and refrigerant piping, follow the installation manual.
When the high pressure piping length is 65 m or less, use 7/8 (22.2) pipe. When the high pressure piping
length exceeds 65 m, use 7/8 (22.2) pipe until 65 m, use 1-1/8 (28.58) pipe for the part that exceeds 65m.
A field provided flow switch is required for minimum flow protection on each module, field installed and
wired to TB8 (terminal 3-4).
*3 If using Circulating water temperatures that are between 23 and 50° F, Dip switch 3-9 must be turned on
and glycol must be used in the water loop to prevent freezing down to 5° F.
*2 Nominal heating conditions (subject to JIS B8615-1)
68degF (20degC)
25ft.(7.6m)
0ft.(0m)
PQRY-P-T(S)LMU, Y(S)LMU (April 2017 Ver2)
PQRY-P240YSLMU-A
3-phase 3-wire 460 ±10% 60Hz
240,000
70.3
16.89
23.5
59~75° F (15~24° C)
50~113° F (10~45° C)
270,000
79.1
14.58
20.3
59~81° F (15~27° C)
50~113° F (10~45° C)
50~150% of heat source unit capacity
57
1-3/8 (34.93) Brazed
PQRY-P120YLMU-A
Galvanized steel sheets
43-5/16 x 34-11/16 x 21-11/16
Inverter scroll hermetic compressor
1,522 + 1,522
25.4 + 25.4
5.76 + 5.76
96 + 96
3.4 + 3.4
793 + 793 ~ 1,902 + 1,902
13.2 + 13.2 ~ 31.7 + 31.7
3.0 + 3.0 ~ 7.2 + 7.2
Over-heat protection, Over-current protection
Over-heat protection
R410A x 11 lbs + 1 oz (5.0 kg)
Indoor LEV and BC controller
3/4 (19.05) Brazed
KJ94T153
Installation Manual
Details refer to External Drw
Heat Source Twinning kit: CMY-Q100CBK2
Unit converter
BTU/h =kW x 3,412
cfm =m 3 /min x 35.31
lb =kg / 0.4536
* Above specification data is subject to rounding
variation.
1,100 x 880 x 550
404 (183)
Plate
1.32
5.0
290
2.0
Inverter
7.7
MEL32
3.48
24
13
20
7/8 (22.2) Brazed
KE94C952
WR2-23