Boot
Boot completes in a minimum of three minutes if POST is run. In addition to POST, boot includes
the following steps after POST is complete:
1.
2.
3.
4.
5.
6.

Regulatory Compliance

FCC Warning (USA only)
This equipment has been tested and complies with the limits for a Class A computing device
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at the user's own
expense.
SilkWorm 3800 Hardware Reference
Universal port configuration is performed.
Links are initialized.
Fabric is analyzed, and if any ports are connected to other switches, the switch participates
in a fabric configuration.
Switch obtains a domain ID and assigns port addresses.
Unicast routing tables are constructed.
Normal port operation is enabled.