Removal
1)
Remove the ACTUATOR NO PAPER (PL15.4.5). (RRP3.14)
2)
Release the HARNESS NO PAPER from the clamp (2 positions)
3)
Release the claw (3 positions) and remove the SENSOR PHOTO (PL15.4.4).
Replacement
Replace the components in the reverse order of removal.
When replacing, secure the left side claw and then replace the claw on the right side.
Chapter 3 Removal and Replacement Procedures
3-97