Summary of Contents for U.S. Products ADVANTAGE 1200
Page 1
ADVANTAGE 1200 240V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
• Use extra care when cleaning on stairs. • Connect to a properly grounded outlet only. • Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure, or chemical content. FORM NO. 56041911 - ADVANTAGE 1200-240V...
Be sure to specify the machine model. Have your serial number handy. Serial Number: __________________ Model: 1200 PSI -240 Purchase Date:_____________ Write the name and phone number of your distributor: ___________________________________________ ___________________________________________ (and be sure to register your purchase to activate your warranty) FORM NO. 56041911 - ADVANTAGE 1200-240V...
Hose Connection Pre-fi lter Bag Power Cords Vacuum Hose Connection Pressure Recovery Adjustment Cap Tank Drain Wheel Latch Pump-out Hose Base Connection Pressure Relief Valve (inside the base Solution compartment) Output Castor FORM NO. 56041911 - ADVANTAGE 1200-240V revised 11/11...
Disconnect the hoses from the cleaning tool. 13. Unplug the power cords. Clean the machine and the tool. Never store your machine outside, and keep it from extremes in temperature. FORM NO. 56041911 - ADVANTAGE 1200-240V...
Page 6
: Use care when handling hazardous chemicals. CAUTION: Never put water hotter than 130 °F / 54 °C in the holding tank. CAUTION : Never leave the 1200 psi pump running when you are not actively using it. FORM NO. 56041911 - ADVANTAGE 1200-240V...
Page 7
11/11 FORM NO. 56041911 - ADVANTAGE 1200-240V...
Page 8
Hose, pump bypass, 3/8” ID X 13” 1160K Pump rebuild kit, valves & O-rings 1160A Pump rebuild kit, plunger and seals * = Optional, Not Included [ ] = Not Shown = Revised or new since last update FORM NO. 56041911 - ADVANTAGE 1200-240V revised 11/11...
Debris is plugging cleaning tool or vacuum hose. LOW SUCTION Drain hose is not completely closed. Vacuum tank lid is not closed or seal is damaged. No power to motor. NO SUCTION Test the switch. Test the vacuum motor. revised 11/11 FORM NO. 56041911 - ADVANTAGE 1200-240V...