Summary of Contents for U.S. Products Advantage 1200
Page 1
ADVANTAGE 1200 EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
IMPORTANT SAFETY INSTRUCTIONS The Advantage 1200 is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops, and offi ces. The Advantage 1200 is not intended for normal residential housekeeping purposes. NOTE: Read all instructions before using this machine.
INSPECTION: Carefully unpack and inspect your ADVANTAGE 1200 for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should notify the carrier immediately if you notice damage to the box, the machine, or its parts.
Page 4
SWITCH PLATE MODEL (1): This identifi es the model of your machine. VACUUM SWITCH (2): MODEL This push-button switch turns on the vacuum. The switch will illuminate when it is on. AUTO DUMP SWITCH (3): This pump switch will illuminate when it is activated, and it will turn on the automatic pump-out pump. SOLUTION PUMP SWITCH (4): The solution pump switch will illuminate when it is activated, and it will turn on the solution pump.
Page 5
SET-UP & OPERATION 1. Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make sure hoses are in good condition and the spray nozzle(s) is tight. 2. If not using the auto-dump feature, just make sure the brass cap is on the drain hose connector on the front of the base of the machine.
Page 6
AUTO VACUUM SHUTOFF: When the recovery tank is full, the ball fl oat will shut-off the suction to prevent the machine from overfl owing. NOTE: the fl oat may not work if there is foam in the tank. Always use defoamer to prevent overfl...
MAINTENANCE SCHEDULE CLEAN ALL FILTERS CHECK POWER CORD FLUSH OUT with DESCALER REPLACE VAC MOTOR BRUSHES Around 1500 hours REPLACE PRESSURE REGULATOR Or as needed Around 1500 hours REBUILD PUMP TROUBLE SHOOTING: IF THIS OCCURS CHECK THIS Solution tank is empty. Clogged spray tip.