1-8. Function of Internal Switches
n
When changing S4 switch setting to the "CAM → CCU" position, be sure to take the following steps.
(1) Disconnect the TRIAX cable from the camera.
(2) Open the left side panel of the camera.
(3) Disconnect the coaxial cable (green) from CN35 (PROMPT) on the DM-97 board.
(4) Reconnect the coaxial cable to CN27 (PROMPT REVERSE) on the MB-764 board. (Insert until it
clicks.)
CN27/MB-764 board
CN35/DM-97 board
Coaxial cable (green)
The coaxial cable has been connected to CN35 on the DM-97 board at the factory.