Download Print this page

Sub - Ver. - BFT SUB EL Installation And User Manual

Piston automations for swing gates
Hide thumbs Also See for SUB EL:

Advertisement

Thank you for buying this product, our company is sure that you will be
more than satisfied with its performance. This product is supplied with a
"WARNINGS" leaflet and an "INSTRUCTION MANUAL". These should both
be read carefully as they provide important information about safety, instal-
lation, operation and maintenance. This product complies with recognised
technical standards and safety regulations. We declare that this product is in
conformity with the following European Directives:
and subsequent amendments.
1) GENERAL OUTLINE
The SUB hydraulic controller provides the ideal solution for underground
hinge-pivot installations, as it brilliantly solves aesthetic automation problems.
The SUB actuator consists of a perfectly sealed single block, containing
a hydraulic control unit and a jack, which provides a hidden underground
installation without any hydraulic connections. The gate is kept closed by an
electric lock, or by a hydraulic lock on the SUB versions supplied with it. The
versions with slow-down functions avoid unpleasant slamming noise when
the gate is brought to the final opening and closing stages. The pushing force
can be adjusted with extreme precision by means of two by-pass valves which
provide antisquash safety. The end-of-stroke operation is electronically set
by a timer on the control panel. The emergency release, activated by the
proper key supplied, can be easily reached after removing the appropriate
cap found on the cover.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives:
89/336/EEC,
ments. As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in order to
achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
The installation must comply with the provisions set out by the following
European Directives:
89/336/EEC,
ments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
INSTALLATION MANUAL
89/336/EEC,
73/23/EEC
73/23/EEC and subsequent amend-
73/23/EEC and subsequent amend-
3,5
mm.
Do not allow persons or children to remain in the automation opera-
tion area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
The motor cannot be installed on gates which incorporate doors (unless
the motor drive can work with the door open).
Take care to avoid possible crushing, due to door movement, between
the guided part and surrounding fixed parts.
If present, the holding device (hold-to-run control) must be fitted within
sight of the guided part and well away from the operator working area.
Unless it is activated by means of a key, it should be positioned at least
1.5 m high and should not be accessible to the public.
Make sure that persons are kept well away from the operator, in particular
whenever the motor is used in «hold-to-run» mode.
Check that the range of temperature indicated is compatible with the
place of installation.
3) MAIN AUTOMATION PARTS
Single-block hydraulic actuator (fig.1) consisting of:
M)
2-pole single-phase motor protected by thermal circuit-breaker.
P)
Hydraulic lobe pump.
D)
Distributor with adjustment valves.
PC)
Rack - pinion jack.
Components supplied as standard: by-pass release and adjustment key,
capacitor, grooved bush and instruction manual.
WARNING: An actuator can be mounted on the left or right-hand side, as
identified by looking at the gate from the inside (opening direction). An actuator
can be recognised as left or right-handed by observing the position of release
pivot "PST". Fig.1 shows an actuator to be mounted on the left.
4) ACCESSORIES
-
CPS Bearing foundation case (provided for automation).
-
CID Non-bearing foundation case.
BSC Slide arm (for mounting to one side of the hinge-pivot).
-
5) TECHNICAL SPECIFICATIONS
Single-phase power supply .................................... 230V~ ±10% 50/60 Hz
Motor revolutions ........................................................................2800 min
Output shaft revolutions ............................................................See Table 1
Absorbed power ............................................................................... 250 W
Capacitor ........................................................................................... 6.3 µF
Absorbed current ................................................................................ 1.4 A
Max torque ......................................................................................400 Nm
Pressure .......................................................................3MPa (30 bar) max
Pump capacity ..........................................................................See Table 1
Impact reaction .................................................................. Hydraulic clutch
Manual manoeuvre ..................................................................Release key
Max no. manoeuvres ............................................................ 500 / 24hours
Thermal protection .......................................................................... 160 °C
Environmental conditions ................................................. -10 °C to +60 C°
Degree of protection .......................................................................... IP 67
Controller weight ....................SUB 220N (~22 kg) - SUB G 240N (~24 kg)
Oil .................................................................................................IDROLUX
Dimensions ................................................................................... See fig.2
(*) Special voltages available on request.
6) ACTUATOR INSTALLATION
6.1) Preliminary checks
Check that:
-
The leaf structure is sturdy and rigid.
-
The upper hinge is in working order and possibly adjustable.
-
A hole can be dug to lay the case under the hinge-pivot, or to one side
of the hinge-pivot for slide arm installation.
-
The leaf ground stop plates are fitted.
-
Repair or replace all faulty or worn components.
Fig.3 illustrates an exploded view of the installation. Automation reliability
and safety are directly affected by the condition of the gate structure.
6.2) Electrical installation setup
Set up the electrical installation as shown in fig.4, making reference to the
current standards for electrical installations. Keep the mains supply connec-
ENGLISH
ENGLISH
-1
13

SUB - Ver. 04 -

Advertisement

loading

This manual is also suitable for:

Sub rSub eSubSub erSub gSub ge ... Show all