7) Abnormality detection by the thermistors
The following table shows the conditions judging the fuser roller temperature abnormality and
detecting timing.
Checking
Priority
timing
On usual
1
Detecting 40°C
1
Detecting 100°C
1
2
Detecting warm-
1
ing-up tempera-
ture
2
During ready sta-
1
tus
2
During copying
1
2
*
The figures in the "priority" section denote the priority of error checking.
e-STUDIO166/206
FUSER / EXIT UNIT
Temperature judged
Center
thermistor
230°C or above
-
230°C or above
-
40°C or below
-
40°C or below
100°C or below
-
100°C or below
40°C or below
150°C or above
150°C or above
40°C or below
Warming-up temp.
or below
-
Warming-up temp.
40°C or below
150°C or above
150°C or above
40°C or below
-
150°C or above
40°C or below
150°C or above
150°C or above
40°C or below
-
150°C or above
40°C or below
-
40°C or below
40°C or below
-
40°C or below
-
13 - 10
Side
thermistor
thermistor
-
-
230°C or above
-
-
-
or below
40°C or below
40°C or below
-
-
-
40°C or below
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
Error-
judging
Edge
timing
-
On usual
-
-
Specified
time
-
-
Specified
time
-
-
On usual
-
-
Specified
time
-
-
On usual
-
-
On usual
-
-
-
-
On usual
-
Error
code
C44
C41
C44
C43
C44
C43
C43
C44
C44
C45