L2 & PA error:
If the "PA" error appears, check the following components.
# Check the condenser fan for correct operation. If the fan motor is not operating check the five pin
connector for correct termination. If the termination of the plug is okay check the continuity of each
voltage point.
Check the Resistance value of the condenser fan motor plug, from the following points.
Note: The following resistance values were measured at an ambient temperature of 20ºC.
Brown & Black = 0.3 Ohms.
Brown & Red = 84.2 Ohms.
Brown & Yellow = 132.0 Ohms.
Brown & Blue = 230 Ohms.