F5, L2 & Pa Error, Test Board - Electrolux Kelvinator KSV26HRB Diagnostic Manual

Table of Contents

Advertisement

F5, L2 & PA error, test board
:
If the F5, L2 & or PA error appears, check the following components.
# Check the condenser fan for correct operation. If the fan motor is not operating check the five pin
connector for correct termination. If the termination of the plug is okay check the resistance value of the
condenser fan motor plug, from the following points.
Note: The following resistance values were measured at an ambient temperature of 25ºC.
Brown & Black = 0.3 Ohms.
Brown & Red = 375 Ohms.
Brown & Yellow = 478 Ohms.
Brown & Blue = 613 Ohms.
Page 18 KSSSI92

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents