E5 Error; E52 Error; Condenser Coil Pipe Temperature Sensor View; Condenser Coil Air Temperature Sensor View - Electrolux KELVINATOR KSV53HRA Diagnostic Manual

Split system reverse cycle air conditioner
Table of Contents

Advertisement

E5 error:

# Check the "condenser coil & compressor discharge sensors" for correct connection.
# Check the continuity of both sensor, if the sensor is open circuit, change it.
Compressor discharge temperature sensor
Condenser coil pipe temperature sensor

E52 error:

# Check the "condenser coil air temperature sensor" for correct connection.
# Check the continuity of the sensor, if the sensor is open circuit, change it.
Condenser coil air temperature sensor
Page 18 KSSSI90

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kelvinator ksv62hraKelvinator ksv70hra

Table of Contents