P91, Lo & E3 Error; Indoor Fan Motor Plug Fitting; 5 Pin Plug Terminal Points - Electrolux KELVINATOR KSV53HRA Diagnostic Manual

Split system reverse cycle air conditioner
Table of Contents

Advertisement

Models: KSV26 & 35HRA Only
P91, LO & E3 error:
If the "P91 & or LO" error appears, check the following components.
# Check the evaporator fan for correct operation. If the fan motor is not operating check the five pin
connector for correct termination. If the termination of the plug is okay check the continuity of each
voltage point.
Check the Resistance value of the evaporator fan motor plug, from the following points:
Note: The following resistance values were measured at an ambient temperature of 20ºC.
Grey & Blue = 37.2 Ohms.
Grey & Yellow = 73.7 Ohms.
Grey & Red = 100.9 Ohms.
Grey & White = 300 Ohms.

5 pin plug terminal points.

Wire colours from left to right:
Grey, Blue, Yellow, Red & White.

Indoor Fan Motor plug fitting.