Indoor Unit & Pcb Test Board Error Display - Electrolux Kelvinator KSV26HRB Diagnostic Manual

Table of Contents

Advertisement

Indoor Unit & PCB test board Error Display.
DISPLAY
LED STATUS
Not
No operation by use of remote control.
Operating
E0
EEPROM parameter error. (Indoor Unit)
F0
Over current error
F4
EEPROM parameter error. (Outdoor Unit)
E1
Indoor / outdoor units communication protection.
Open or short circuit of outdoor condenser pipe, outdoor ambient temperature & compressor
F1, F2 & F3
temperature sensors.
E4 & E5
Open or short circuit of room or evaporator temperature sensors.
F5, L2 & PA High & Low-temperature protection of condenser / Outdoor fan motor feedback circuit error.
P0
Module protection.
P2
Temperature protection of compressor top - low refrigerant charge.
P4
Inverter compressor drive error.
P1
Over voltage or too low voltage protection.
E3
Indoor fan motor circuit error.
Page 2 KSSSI92
PAGE
3
4
4
5
6 to 14
15 & 16
17
18 & 19
20
219
22 & 23
23