Electrical Connection, Disposal - Hotpoint MWH424.1X Service Information

Built in combination microwave ovens electronic with touch & variable control
Hide thumbs Also See for MWH424.1X:
Table of Contents

Advertisement

Indesit
Company
ELECTRICAL CONNECTION
The following pages are taken from the User Instruction Book.
DANGER
Electric Shock Hazard.Touching some of the internal components can cause serious personal injury or
death. Do not disassemble this appliance.
WARNING
The electrical connections must be made before installing the appliance in its housing.
Electrical safety must be guaranteed by correct installation in the housing. During installation and
maintenance operations, the appliance must be disconnected from the mains circuit-breaker or the
fuses must be removed.
The appliance must be connected using a power cable equipped with 3 1.5mm2 conductors (Live +
Neutral + Earth), H05RR-F 300V/500V specification, connected to a single phase 230-240V~network
in accordance with installation requirements. The safety wire (Green-Yellow) is connected to the
appliance's Earth terminal and must be connected to the installation Earth.
If the appliance has an electrical connection, it must remain accessible after the appliance has been
built in.
The oven's neutral (blue wire) must be connected to the network's neutral.
It must be possible to disconnect the appliance from the power supply, by fitting a switch on the fixed
wiring system in accordance with installation rules.
Ensure that:
-
The electrical power has sufficient voltage. - the power cable is in good condition;
-
The diameter of the wires complies with installation requirements.
-
The electrical installation is equipped with protection of at least 16 amps.
CAUTION
Personal Injury Hazard
It is hazardous for anyone other than a competent person to carry out any service or repair operation
that involves the removal of a cover which gives protection against exposure to microwave energy.
Please observe the installation instructions provided and note that this appliance should only be
installed by an approved qualified installer.
In case a new connection is needed, installation and cable connection must only be done by an
approved qualified installer. If the connection is no longer accessible following installation, a
double-pole disconnecting device must be present on the installation site with a contact gap of at
least 3 mm.
Adaptors, multiway strips and extension cables must not be used. Overloading can result in fire.