Titan ED655 Owner's Manual page 3

Airless diaphragm pump
Hide thumbs Also See for ED655:
Table of Contents

Advertisement

Important Safety Information
8. Check hoses and parts for signs of damage, a leak can
inject material into the skin. Inspect hose before each use.
Replace any damaged hoses or parts.
9. This system is capable of producing 2750 PSI / 190
Bar. Only use replacement parts or accessories that
are specified by the manufacturer and that are rated a
minimum of 2750 PSI. This includes spray tips, nozzle
guards, guns, extensions, fittings, and hose.
10. Always engage the trigger lock when not spraying. Verify
the trigger lock is functioning properly.
11. Verify that all connections are secure before operating the
unit.
12. Know how to stop the unit and bleed pressure quickly. Be
thoroughly familiar with the controls. Pressure will not be
released by turning off the motor. The PRIME/SPRAY
valve or pressure bleed valve must be turned to their
appropriate positions to relieve system pressure. Refer
to PRESSURE RELIEF PROCEDURE described in the
pump manual.
13. Always remove the spray tip before flushing or cleaning
the system.
NOTE TO PhYSIcIaN:
Injection into the skin is a traumatic injury. It is important
to treat the injury as soon as possible. DO NOT delay
treatment to research toxicity. Toxicity is a concern with
some coatings injected directly into the blood stream.
consultation with a plastic surgeon or reconstructive
hand surgeon may be advisable.
d) waRNING - To reduce the risk of injury:
1. Always wear appropriate gloves, eye protection, clothing
and a respirator or mask when painting. Hazardous
vapors – Paints, solvents, insecticides, and other materials
can be harmful if inhaled or come in contact with body.
Vapors can cause severe nausea, fainting or poisoning.
2. Do not operate or spray near children. Keep children
away from equipment at all times.
3. Do not overreach or stand on an unstable support. Keep
effective footing and balance at all times.
4. Stay alert and watch what you are doing.
5. Do not operate the unit when fatigued or under the
influence of drugs or alcohol.
6. Do not kink or over-bend the hose. Airless hose can
develop leaks from wear, kinking and abuse. A leak can
inject material into the skin.
7. Do not expose the hose to temperatures or pressures in
excess of those specified by manufacturer.
8. Do not use the hose as a strength member to pull or lift the
equipment.
9. Use lowest possible pressure to flush equipment.
10. Follow all appropriate local, state and national codes
governing ventilation, fire prevention and operation.
11. The United States Government Safety Standards have
been adopted under the Occupational Safety and Health
Act (OSHA). These standards, particularly part 1910 of
the General Standards and part 1926 of the Construction
Standards should be consulted.
12. Before each use, check all hoses for cuts, leaks, abrasion
or bulging of cover. Check for damage or movement
of couplings. Immediately replace hose if any of those
conditions exist. Never repair a paint hose. Replace with
a conductive high-pressure hose.
13. Do not spray outdoors on windy days.
14. Always unplug cord from outlet before working on
equipment (electric models only).
© Titan Tool Inc. All rights reserved.
operating the equipment. SavE ThESE INSTRucTIONS.
·
Read all safety information before
Important Electrical Information
ImPORTaNT: Use only a 3-wire extension cord that has
a 3-blade grounding plug and a 3-slot receptacle that will
accept the plug on the product. Make sure your extension
cord is in good condition. When using an extension cord,
be sure to use one heavy enough to carry the current your
product will draw. an undersized cord will cause a drop
in line voltage resulting in loss of power and overheating.
a 14 or 12 gauge cord is recommended (see chart). If an
extension cord is to be used outdoors, it must be marked
with the suffix W-A after the cord type designation. For
example, a designation of SJTW-A would indicate that the
cord would be appropriate for outdoor use.
Cord gauge
12
14
ImPORTaNT: This unit is provided with a thermally
protected automatic reset. If an overload occurs the
thermally protected automatic reset disconnects the motor
from the power supply.
• The motor will restart without warning when the protector
automatically resets.
• Always disconnect the motor from the power supply before
working on the equipment.
• When the thermally protected automatic reset disconnects
the motor from the power supply, relieve pressure by
turning the priming valve to PRIME.
• Turn the ON/OFF switch to OFF.
NOTE: The cause of the overload should be corrected
before restarting. See Troubleshooting.
Specifications
Weight ...................................... 27 lbs
Capacity.................................... Up to .35 gallon (1.25 liters) per
Power source............................ Electric motor, totally enclosed,
Power requirement ................... 15 amp minimum circuit on 115
Generator ................................. 15 amp A/C.
Spraying pressure .................... Up to 2750 PSI
Capabilities ............................... Sprays a variety of oil-based and
3
Maximum cord length
150 feet
100 feet
minute
fan cooled
VAC, 60 Hz current.
latex paints, primers, and stains

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents