Operation; Digital Temperature Controller And Control Panel; Switching The Appliance On; Control Panel Buttons - Electrolux Prostore PS06R1F User Manual

1 door digital refrigerator 800l
Hide thumbs Also See for Prostore PS06R1F:
Table of Contents

Advertisement

C.1 Operation
C.1.1 Digital temperature controller and control panel
Fig. 1
Fig. 2
The digital temperature controller has a button for switching
the appliance on and o ( g.1) and 6 buttons for control and
programming the instrument (see g. 2).
C.1.1.1 Switching the appliance on
Connect the power cable to a power outlet.
The instrument display does a Lamp Test
and the message OFF appears. To activate
and deactivate the appliance press the
button for 5 seconds.
The display will show the message ON (for
activation) or OFF (for deactivation). Even
if the machine is deactivated with the On
and O button it still remains powered.
This switch only disconnects the power
to the loads connected to the instrument.
C.1.1.2 Control panel buttons ( g. 2)
History button
It memorises the temperature every 24
hours from switch-on for a total of 62
memorisations. It memorises high/low
temperature alarms. Press the History but-
ton once to access the list of daily memo-
rised values (t0 = current day; t1, t2,
t3,etc.=previous memorisation days). With
the buttons it is possible to view the tem-
peratures of previous days.
Press the button Set to display the mem-
orised temperature of that period; press
the button P to return to the list of stored
values.
Press the button P for a few seconds to exit
the History function. After the installation
of the appliance, at least 24 hours must
pass for the rst temperature to be record-
ed. Holding down the button for a few
seconds will reset the previous memorisa-
tions.
Programs button
It is used in the HISTORY function (see
par. C.1.1.2).
Press the button P to also access the
Technical Menu, which cannot be modi ed.
Humidity button
IT IS available in refrigerated models only
and is used to set 3 di erent humidity
levels. Depending on the humidity level
the display will show images with 1, 2 or
3 lines that indicate: low, medium and
high humidity.
1 line (30%)
2 lines (60%)
3 lines (90%)
Use the buttons to select the most suitable
humidity level.
Table of categories, compartment temperature and
humidity setting
Categories
Fresh meat (beef, mutton, pork)
Poultry
Fruit & Veg
Eggs, butter, cheese, charcuterie
Fresh sh
Patisserie
Beverages
To con rm the degree of humidity selected,
press the button Set for 5 seconds.
Set button
If pressed for more than 1 second it displays
and/or sets the set point. To increase or
decrease the values , use the buttons
To con rm the new value, press the button
Set again.
Continuous cycle button
Pressing the button for more than 5 sec-
onds activates the "TC" Turbo Cooling cycle
function (the message ccb=start appears),
or activates the temperature reset function,
skipping Defrost. During the continuous
cycle the compressor always stays on; the
low temperature alarm is deactivated; the
message TC and the temperature value
alternate on the display. The continuous
cycle ends when:
the button is pressed (the message
`
`
cce=end appears);
the lowest foreseen temperature is
`
`
reached;
the maximum duration is reached
`
`
(time 1h);
the instrument is switched o .
`
`
Temp.°C
Humidity
4
90%
-2
90%
6
90%
6
90%
4
90%
6
90%
8
60%
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents