B.2 Installation and assembly
To ensure correct operation of the appliance and maintain
safe conditions during use, carefully follow the instructions
given below in this section.
ATTENTION
The above operations must
be carried out by the spe-
cialised technician in con-
formity with the current
safety regulations, regard-
ing the equipment used and
the operating procedures.
Before moving the appli-
ance make sure the capacity
of the lifting equipment
used is suitable for its
weight.
Keep the ventilation openings in the appliance
casing or in the installation structure free of
any obstructions.
B.2.1 The customer's responsibilities
The tasks and works required of the Customer are:
arrange an earthed power socket of suitable capacity for
`
`
the input speci ed on the data plate;
for information regarding the electrical connection, refer
`
`
to par. B.2.8 "Electrical connection";
check the atness of the surface on which the machine
`
`
is placed.
B.2.2 Machine space limits
A suitable space must be left around the machine (for opera-
tions, maintenance, etc.). This space must be increased in case
of use and/or transfer of other equipment and/or means or
if exit routes are necessary inside the workplace. Refer to par.
"B.2.3 Positioning" for information regarding distances from any
other machines present in the room (in fact, close proximity
can create problems of condensate forming on the walls of the
appliance), also taking into consideration the space needed
for door opening.
B.2.3 Positioning
Install the appliance, taking all the safety precautions required
for this type of operation, also respecting the relevant re-pre-
vention instructions.
Install the appliance in a ventilated place, away from heat
sources such as radiators or air conditioning systems, to allow
correct cooling of the refrigerating unit components.
When positioning to take into account the following
distances:
at least 50 cm from the top;
`
`
50 cm from the sides and back.
`
`
min. 50 cm
min.
50
cm
ATTENTION
The plug must be accessi-
ble after positioning the
appliance in the place of
installation.
Never cover the condenser, even temporarily, as this can
compromise proper operation of the condenser and there-
fore the appliance.
If the machine is installed in a place where there are corro-
sive substances (chlorine, etc.), it is advisable to go over all
the stainless steel surfaces with a rag soaked in para n oil to
create a protective lm.
For information regarding the room temperatures in which
the machine must operate, refer to par. A.2.1 "Climatic class".
The machine must be taken to the place of installation and the
packing base removed only when being installed.
Arranging the machine:
position the machine in the required place;
`
`
adjust the height and levelling with the adjustment feet,
`
`
also checking correct door closing
ATTENTION
The appliance must be levelled, otherwise its
operation could be a ected.
min.
50
cm