10. COMPONENT TESTING INFORMATION

10.4 PUMP

Circuit in the PCB / Wiring Diagram
Wiring
diagram
Function
The pump are used to drain the tub and to circulate the water
Test points
and result
1 2
Test points
Result
Remarks
1-2
179±10% Ω
42