8. TEST MODE
8.2.4 Test mode
When the "Test mode" is turned on and the program is running,
♦ Press the "Spin" button to turn on/off the acceleration function, the running of
program will be accelerated up to 10 times, with two ":" icons flickering;
♦ Press the "Temp." button to turn on/off the temperature display function, with
water temperature displayed.
♦ Continuously press the "Function" button to successively display the current
"equilibrium value, the current speed, the current water-level frequency, the
heater status (H0: No heating, H1: Heating), return-to-normal display, the
current equilibrium value......". If there is no valid equilibrium value for display,
then it will display "Un‐‐".
8.2.5 Cycle mode
♦ After the "Cycle mode" (To be used for double-85 test and complete machine
life test) is turned on, and the washing course is completed, wait for 10 seconds,
and then the program will automatically re-run.
♦ After the "Cycle mode" is turned on, the display window displays the program
run cycle number for 1 second upon each startup. Display in decimal system,
with the maximum valve up to 9999.