Lennox G71MPP-36B-070 Installation Instructions Manual page 49

G71mpp series units
Hide thumbs Also See for G71MPP-36B-070:
Table of Contents

Advertisement

TABLE 30
G71MPP-60D-135
BLOWER PERFORMANCE
(less filter) -- Single Side Return Air
(Air volumes in bold require field fabricated transition to accommodate
20 x 25 x 1 in. cleanable air filter
in order to maintain proper air velocity across the filter.)
0 through
0.80 in. w.g. External
Static Pressure
Range
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)
Heat CFM
Decrease (-15%)
Heat CFM
Heating Input Range and Blower Volume - CFM
50%
1160
1075
1005
93O
85O
60%
1325
1225
1145
1060
970
80%
1640
1520
1425
1325
1215
90%
1790
1670
1570
1470
1345
COOLING BLOWER PERFORMANCE
Blower Speed Selections
Cooling Adjust CFM
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Selections
Medium-
Medium
High
Medium-
Medium
High
Low
Low
High
(Default)
Low
Low
High
(Default)
Increase (+10%) Cool CFM
1105
1180
1330
1500
1585
1705
1905
2130
Default Cool CFM
990
1075
1210
1355
1430
1545
1765
1975
Decrease (-10%) Cool CFM
890
950
1085
1210
1275
1370
1565
1755
The effect of static pressure is included in air volumes shown,
Lennox Harmony Ill " Zone Control Applications
- Minimum blower speed is 450 cfm.
The following control configurations
are available, See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance
Table):
With a single-stage thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey-shaded
columns),
With two-stage
thermostat there are two modes available.
Traditional two-stage mode - W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey-shaded columns only).
Variable Rate Capacity Mode - furnace automatically
adjusts firing rate based on first- and second-stage
cycle times. (all columns)
Cool Mode (Cooling Blower Perfomance table):
First stage COOL (two-stage air conditioning
units only) is approximately
70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately
28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage
COOL speed position
minimum 450 cfm.
G71MPP-60D-135
BLOWER MOTOR WATTS - COOLING
Motor Watts @ Various External Static Pressures - in. wg.
Blower Speed
First Stage
10.1010.2010.3010.4010.5010.6010.7010.80
0
10.1010.2010.3oOndS/a0.5010.6010.7010.80Sectge
Options
0
I 0.40
Increase (+10%) Cool CFM
Low
90
110
140
170
195
220
240
265
290
230
265
310
355
390
425
460
490
525
Medium-Low
105
130
165
195
215
235
260
290
315
285
330
380
430
455
485
525
565
605
Medium-High
150
175
205
235
270
300
330
360
385
425
465
515
560
605
645
685
730
770
High
195
230
270
305
340
375
410
445
480
605
650
695
740
800
855
900
945
985
Default Cool CFM
Low
Medium-Low
Medium-High
High
Decrease (-10%) Cool CFM
Low
Medium-Low
Medium-High
High
455
5O5
645
810
36O
42O
510
635
Page 49