TABLE 29
G71MPP-60D-135
BLOWER PERFORMANCE
(less filter)
Bottom
Return Air, Return Air from Both Sides or Return Air from Bottom
and One Side
0 through
0.80 in. w.g. External Static Pressure
Range
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)
Heat CFM
Decrease (-15%)
Heat CFM
Heating
Input Ran
50%
60%
1220
1390
1130
1290
1045
1195
975
1110
890
1020
e and Blower Volume - CFM
80%
1725
1600
1495
1390
1275
90%
1885
1750
1650
1535
1405
COOLING
BLOWER
PERFORMANCE
Blower
Speed
Selections
Cooling
Adjust
CFM
First Stage
Cool
Speed
- cfm
Second
Stage
Cool Speed
- cfm
Selections
Medium-
Medium
High
I Medium-
I Medium
I
High
Low
Low
High
(Default)
Low
Low
High
(Default)
i
i
i
Increase
(+10%)
Cool
CFM
1135
1205
1365
1540
1615
1730
1945
2190
Default
Cool
CFM
1025
1105
1235
1390
1455
1580
1780
1985
Decrease
(-10%)
Cool
CFM
915
985
1115
1235
1305
1400
1600
1780
The effect of static pressure is included in air volumes shown.
Lennox Harmony Ill _ Zone Control Applications - Minimum blower speed is 450 cfm.
The following control configurations
are available. See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance
Table):
With a single-stage thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey-shaded
columns),
With two-stage thermostat there are two modes available,
Traditional two-stage mode - W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey-shaded columns only).
Variable Rate Capacity Mode - furnace automatically
adjusts firing rate based on first- and second-stage
cycle times. (all columns)
Cool Mode (Cooling Blower Perfomance table):
First stage COOL (two-stage air conditioning units only) is approximately
70% of the same second stage COOL speed position.
Continuous
Fan speeds are approximately
28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage
COOL speed position
minimum 450 cfm.
G71 MPP-60D-135
BLOWER
MOTOR
WATTS
- COOLING
Bottom
Return
Air, Return
Air from
Both
Sides
or Return
Air from
Bottom
and One Side
I
Motor
Watts
@ Various
External
Static
Pressures-in.
wg.
Blower
Speed
First Stage
/
Options
0 10.10
10.20
10.30
10.40
10.50
10.60
10.70
10.80
Increase
(+10%)
Cool
CFM
Low
Medium-Low
Medium-High
High
Default
Cool
CFM
Low
Medium-Low
Medium-High
High
Decrease
(-10%)
Cool
CFM
Low
Medium-Low
Medium-High
High
Second
Stage
0 10.1010.2010.3010.4010.5010.6
515
6O5
75O
98O
43O
5OO
625
775
355
415
515
610
Page 48