Lennox G71MPP-36B-070 Installation Instructions Manual page 45

G71mpp series units
Hide thumbs Also See for G71MPP-36B-070:
Table of Contents

Advertisement

TABLE 26
G71 MPP-60C-110
BLOWER PERFORMAN CE (less filter)
Bottom
Return Air, Return Air from Both Sides or Return Air from Bottom
and One Side
0 through
0.80 in. w.g. External
Static Pressure
Range
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)
Heat CFM
Decrease (-15%)
Heat CFM
Heating Input Range and Blower Volume - CFM
50%
1050
975
96O
86O
79O
60%
1215
1125
1075
99O
910
80%
1535
1430
1335
1250
1145
90%
1695
1585
1480
1380
1260
COOLING BLOWER PERFORMANCE
Blower Speed Selections
Cooling Adjust CFM
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Selections
Medium-
Medium
High
Medium-
Medium
High
Low
Low
High
(Default)
Low
Low
High
(Default)
Increase (+10%) Cool CFM
945
1020
1160
1300
1625
1745
1990
2210
Default Cool CFM
840
910
1055
1180
1465
1580
1790
1995
Decrease (-10%) Cool CFM
740
800
920
1045
1290
1405
1605
1790
The effect of static pressure is included in air volumes shown,
Lennox Harmony Ill _ Zone Control Applications
- Minimum blower speed is 450 cfm,
The following control configurations
are available, See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance
Table):
With a single-stage
thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey-shaded
columns),
With two-stage thermostat there are two modes available.
Traditional two-stage mode - W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey-shaded columns only),
Variable Rate Capacity Mode - furnace automatically
adjusts firing rate based on first- and second-stage
cycle times. (all columns)
Cool Mode (Cooling Blower Perfomance table):
First stage COOL (two-stage air conditioning
units only) is approximately
70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately
28%, 38%, 70% and 100% (DiP switch selectable) of the same second-stage
COOL speed position
minimum 450 cfm
G71MPP-60C-110
BLOWER MOTOR WATTS -COOLING
Bottom
Return Air, Return Air from Both Sides or Return Air from Bottom
and One Side
Motor Watts @ Various
External
Static Pressures
- in. wg.
Blower Speed
First Stage
10.1010.2010.3010.4010.5010.6010.7010.80
0
10.1010.2010.3oOndS/a0.5010.6010.7010.80sectge
Options
0
10.40
Increase (+10%) Cool CFM
Low
75
90
115
135
160
180
200
220
240
280
315
350
390
430
475
510
550
585
Medium-Low
90
105
130
150
175
200
220
245
270
340
380
425
465
505
545
575
610
645
Medium-High
120
140
170
195
225
250
275
300
330
510
545
585
620
675
735
770
805
840
High
160
185
210
235
265
290
325
360
395
710
755
805
855
905
950
980
101
1035
Default Cool CFM
Low
55
70
90
110
135
155
175
195
215
205
235
275
310
345
380
415
450
485
Medium-Low
75
90
105
125
150
170
190
215
235
250
285
325
360
400
440
470
505
540
Medium-High
95
115
135
160
190
220
240
265
285
375
410
445
485
530
575
605
635
670
High
125
150
175
200
225
255
280
305
335
510
550
595
640
685
725
770
815
860
Decrease (-10%) Cool CFM
Low
45
60
80
100
115
125
145
160
180
155
180
210
240
270
295
325
355
385
Medium-Low
55
70
85
105
125
150
165
185
200
185
215
245
280
315
345
380
415
450
Medium-High
70
85
105
125
150
170
195
215
235
265
300
345
385
425
465
500
535
570
High
95
110
135
160
190
220
240
260
280
375
415
455
495
535
575
615
650
690
Page 45