Lennox G71MPP-36B-070 Installation Instructions Manual page 47

G71mpp series units
Hide thumbs Also See for G71MPP-36B-070:
Table of Contents

Advertisement

TABLE 28
G71MPP-60C-110
BLOWER PERFORMANCE
(less filter) -- Side Return Air with Optional RAB Return Air Base
0 through
0.80 in. w.g. External
Static Pressure
Range
HEATING
BLOWER
PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)
Heat CFM
Decrease (-15%)
Heat CFM
Heating Input Range and Blower Volume - CFM
50%
1020
950
895
835
765
60%
1175
1095
1030
96O
88O
80%
1485
1385
1300
1210
1110
90%
1635
1535
1435
1335
1220
COOLING BLOWER PERFORMANCE
Blower Speed Selections
Cooling Adjust CFM
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Selections
Medium-
Medium
High
Medium-
Medium
High
Low
Low
High
(Default)
Low
Low
High
(Default)
Increase (+10%) Cool CFM
1085
1155
1310
1475
1555
1685
1895
2130
Default Cool CFM
955
1050
1185
1335
1415
1540
1735
1930
Decrease (-10%) Cool CFM
850
920
1070
1195
1245
1350
1545
1725
The effect of static pressure is included in air volumes shown,
Lennox Harmony Ill _' Zone Control Applications
- Minimum blower speed is 450 cfm.
The following control configurations
are available. See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance
Table):
With a single-stage
thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey-shaded
columns).
With two-stage thermostat there are two modes available.
Traditional two-stage mode - W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey-shaded columns only).
Variable Rate Capacity Mode - furnace automatically
adjusts firing rate based on first- and second-stage
cycle times. (all columns)
Cool Mode (Cooling Blower Perfomance table):
First stage COOL (two-stage air conditioning
units only) is approximately
70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately
28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage
COOL speed position
minimum 450 cfm.
G71MPP-60C-110
BLOWER MOTOR WATTS - COOLING - Side Return Air with Optional RAB Return Air Base
Motor Watts @ Various External Static Pressures - in. wg.
Blower Speed
First Stage
Second Stage
Options
0 10.1010.2010.3010.4010.5010.8010.7010.80
0 1010102010301040105010801
Increase (+10%) Cool CFM
Low
105
125
150
175
200
220
245
265
290
250
285
320
360
395
435
470
500
535
Medium-Low
130
150
175
200
220
240
270
295
320
335
365
405
445
480
515
550
590
630
Medium-High
165
190
220
250
275
305
335
370
400
470
505
545
585
630
670
710
755
800
High
205
240
285
330
360
390
420
450
485
655
695
745
790
840
885
925
965
1005
Default Cool CFM
Low
75
90
115
135
160
185
205
225
250
190
220
255
290
325
360
395
430
460
Medium-Low
100
120
145
165
185
205
230
255
280
250
285
325
360
390
420
455
485
520
Medium-High
135
155
175
200
230
260
280
305
330
355
395
435
475
510
545
580
620
660
High
170
195
225
255
290
320
350
375
405
475
515
565
610
655
705
745
785
825
Decrease (-10%) Cool CFM
Low
55
70
90
110
135
155
175
195
220
150
170
200
225
255
285
315
340
370
Medium-Low
65
80
105
130
150
170
195
215
240
165
195
230
265
300
330
360
390
420
Medium-High
100
125
150
180
200
220
240
260
280
240
280
320
360
400
435
470
505
540
High
140
160
180
200
230
260
285
305
330
350
385
420
455
500
540
575
610
645
Page 47