Blower Motor Performance; Heating Blower Performance; Cooling Blower Performance - Lennox G71MPP-36B-070 Installation Instructions Manual

G71mpp series units
Hide thumbs Also See for G71MPP-36B-070:
Table of Contents

Advertisement

TABLE 21
G71MPP-36B-070
BLOWER PERFORMANCE
(less filter)
0 through
0.80 in. w.g. External Static Pressure
Range
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)
Heat CFM
Decrease (-15%)
Heat CFM
iiiiiiiiiiiiiiiiiiiiiiiiiiiiii
! !
!ii! i! i! i! i! i! i! i! i! i! i! i! i! i! i! i! i! !i
Heating Input Ran
50%
60%
610
690
575
645
545
610
52o
58o
490
54o
e and Blower Volume - CFM
80%
87O
810
76O
715
655
9O%
975
9O5
845
79O
715
COOLING BLOWER PERFORMANCE
Blower Speed Selections
Cooling Adjust CFM
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Selections
Medium-
Medium
High
I Medium-
I Medium
I
High
Low
Low
High
(Default)
Low
Low
High
(Default)
Increase
(+10%) Cool CFM
730
815
865
935
1015
1190
1280
1395
Default Cool CFM
880
755
795
855
930
1065
1155
1270
Decrease (-10%) Cool CFM
625
695
730
775
830
950
1010
1105
The effect of static pressure is included in air volumes shown.
Lennox Harmony Ill _ Zone Control Applications - Minimum blower speed is 250 cfm.
The following control configurations
are available. See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance
Table):
With a single-stage thermostat, furnace will operate at three, staged rates (40/70/100%)
with a time delay between each stage (values in grey-shaded
columns).
With two-stage thermostat there are two modes available.
Traditional two-stage mode - W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey-shaded columns only).
Variable Rate Capacity Mode - furnace automatically
adjusts firing rate based on first- and second-stage
cycle times. (all columns)
Cool Mode (Cooling Blower Perfomance table):
First stage COOL (two-stage air conditioning units only) is approximately
70% of the same second stage COOL speed position.
Continuous
Fan speeds are approximately
28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage
COOL speed position
minimum 250 cfm,
G71MPP-36B-070
BLOWER MOTOR WATTS - COOLING
I
Motor Watts @ Various
External Static Pressures-in.
wg.
Blower Speed
First Stage
/
10.1010.2010.3010.4010.5010.6010.7010.80 0 [0.1010.2010.30ondS/ao.5010.6010.7010.8
osec
tge
Options
0
[ 0.40
Increase (+10%) Cool CFM
Low
55
70
90
110
130
145
160
175
190
135
155
175
200
220
245
270
295
320
Medium-Low
75
90
110
130
150
170
190
205
220
185
215
250
285
315
345
370
395
420
Medium-High
85
100
120
145
165
185
205
225
250
235
265
300
335
370
400
425
455
480
High
105
125
150
170
190
210
235
255
280
315
340
370
395
440
480
510
540
570
Default Cool CFM
Low
45
60
80
95
115
130
145
160
175
100
120
140
165
190
215
235
255
275
Medium-Low
60
75
95
110
130
145
165
180
200
140
165
190
220
245
265
290
315
340
Medium-High
65
85
105
125
140
155
175
195
215
175
200
230
260
285
310
340
365
390
High
85
100
120
140
160
180
200
220
240
230
260
295
325
360
390
410
435
455
Decrease (-10%) Cool CFM
Low
40
55
70
85
100
120
130
145
160
75
90
110
125
150
175
190
210
225
Medium-Low
45
60
80
95
115
135
145
160
175
95
120
150
175
200
220
240
260
285
Medium-High
50
65
85
105
125
145
160
175
190
125
150
175
195
220
240
265
290
320
High
60
75
95
115
135
150
170
190
215
165
190
215
245
265
485
315
340
370
Page 40