TABLE 23
G71MPP-60C-090
BLOWER PERFORMANCE
(less filter)
Bottom
Return Air, Return Air from Both Sides or Return Air from Bottom
and One Side
0 through
0.80 in. w.g. External Static Pressure
Range
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)
Heat CFM
Decrease (-15%)
Heat CFM
iiiiiiiiiiiiiii_i_;!i;ii:ii:i_:i_!_i!_!i!i_i_i_i_i_i_i_i_i_i_!_!_i_i_f_ii_
iiiiiiiiiiiiiiiiiiiii i i!iii ii!i!! ! !ii i
i i i i i i i ii i ! ii!i !ii!ii! iii iiii i
Heating
Input
Ran
50%
60%
800
935
730
860
715
820
630
740
565
665
e and Blower Volume - CFM
80%
1205
1110
1035
96O
87O
90%
1335
1235
1150
1070
97O
COOLING
BLOWER
PERFORMANCE
Blower
Speed
Selections
Cooling
Adjust
CFM
First
Stage
Cool
Speed
- cfm
Second
Stage
Cool
Speed
- cfm
Selections
Medium-
Medium
High
I Medium-
I Medium
I
High
Low
Low
High
(Default)
Low
Low
High
(Default)
Increase
(+10%)
Cool
CFM
1105
1185
1355
1545
1605
1710
1925
2165
Default
Cool
CFM
995
1080
1205
1345
1440
1560
1755
1960
Decrease
(-10%)
Cool
CFM
890
960
1090
1215
1275
1380
1590
1755
The effect of static pressure is included in air volumes shown.
Lennox Harmony Ill " Zone Control Applications - Minimum blower speed is 450 cfm,
The following control configurations
are available. See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance
Table):
With a single-stage thermostat, furnace will operate at three, staged rates (40/70/100%)
with a time delay between each stage (values in grey-shaded
columns),
With two-stage thermostat there are two modes available,
Traditional two-stage mode - W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey-shaded columns only).
Variable Rate Capacity Mode - furnace automatically
adjusts firing rate based on first- and second-stage
cycle times. (all columns)
Cool Mode (Cooling Blower Perfomance table):
First stage COOL (two-stage air conditioning units only) is approximately
70% of the same second stage COOL speed position.
Continuous
Fan speeds are approximately
28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage
COOL speed position
minimum 450 cfm.
G71MPP-60C-090
BLOWER MOTOR WATTS - COOLING
Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side
I
Motor Watts @ Various
External Static Pressures-in.
wg.
Blower Speed
First Stage
/
10.1010.2010.3010.4010.5010.6010.7010.80
0
10.1010.2010.3oOndSa0.5010.6010.7010.80Sectge
Options
0
10.40
Increase (+10%) Cool CFM
Low
115
135
160
185
205
230
255
275
300
305
340
375
410
440
475
505
535
565
Medium-Low
145
165
190
215
240
265
285
305
325
355
390
430
470
510
550
580
610
635
Medium-High
170
200
240
275
305
335
370
400
430
510
555
600
645
690
730
765
795
830
High
265295330365400435465500535725780835895935975
100
1031065
Default Cool CFM
Low
90
110
130
155
175
195
215
235
255
220
250
285
320
350
385
415
450
485
Medium-Low
110
130
155
180
200
220
245
265
285
270
305
345
385
420
455
485
515
545
Medium-High
145
165
190
215
245
270
295
320
340
390
425
465
500
540
580
610
640
670
High
180
205
240
270
300
330
365
395
430
540
580
625
670
710
755
795
830
870
Decrease (-10%) Cool CFM
Low
70
85
105
125
145
165
185
205
225
160
190
220
255
275
300
330
360
390
Medium-Low
80
100
120
140
165
190
210
225
245
195
225
260
295
325
350
385
415
450
Medium-High
110
130
160
185
205
225
250
275
300
295
330
365
400
430
460
495
535
570
High
155
175
195
220
245
270
295
315
340
400
435
470
510
545
585
610
640
665
Page 42