Lennox LI012CI-230P432 Owner's Manual
Hide thumbs Also See for LI012CI-230P432:

Advertisement

LENNOX
LI012CI-230P432
LI018CI-230P432
LI024CI-230P432
LI012HI-230P432
LI018HI-230P432
LI024HI-230P432
LENNOX
LI012CO-230P432
LI018CO-230P432
LI024CO-230P432
LI012HO-230P432
LI018HO-230P432
LI024HO-230P432

Advertisement

Table of Contents
loading

Summary of Contents for Lennox LI012CI-230P432

  • Page 1 LENNOX LI012CI-230P432 LI012CO-230P432 LI018CI-230P432 LI018CO-230P432 LI024CI-230P432 LI024CO-230P432 LI012HI-230P432 LI012HO-230P432 LI018HI-230P432 LI018HO-230P432 LI024HI-230P432 LI024HO-230P432 LENNOX...
  • Page 2: Table Of Contents

    Content Operation Notices Precautions......................1 Parts name ......................6 Screen Operation Guide Buttons on remote controller .................8 Introduction for icons on display screen ..............8 Introduction for buttons on remote controller ............9 Function introduction for combination buttons .............12 Operation guide ....................14 Replacement of batteries in remote controller .............14 Emergency operation ..................
  • Page 3: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 4 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 5 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 6 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 7 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 8: Parts Name

    Parts Name Indoor Unit air inlet panel aux.button air outlet H O U R ONOFF remote control (Display content or position may be different from above graphics, please refer to actual products) NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 9 Parts Name Display For some model: For some model: temp. cooling power receiver indicator indicator indicator window heating indicator display cooling indicator receiver power heating temp. drying window indicator display indicator indicator indicator drying indicator For some model: display temp. indicator Power LED color indicator: Green-status-ON.
  • Page 10: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button - button + button MODE button H O U R ONOFF FAN button SWING button I FEEL button button SLEEP button TEMP button TIMER-ON button CLOCK button TIMER-OFF button TURBO button LIGHT button X-FAN button Introduction for icons on display screen X-fan set fan speed...
  • Page 11: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: indicator " " is ON (red indicator). You can operate the air conditioner through the remote controller. indicates the signal has been sent to air conditioner. ON/OFF button Press this button to turn on the unit. Press this button again to turn off the unit. - button Press this button to decrease set temperature.
  • Page 12 Introduction for buttons on remote controller FAN button Auto High speed Low speed Medium speed SWING button will carry out the command as indicates the guide louver swings as: I FEEL button Press this button to turn on I FEEL function. The unit automatically adjust tempera- ture according to the sensed temperature.
  • Page 13 Introduction for buttons on remote controller TEMP button by remote controller as below: no display indoor unit displays set temperature. displays indoor ambient temperature. displays outdoor ambient temperature. Note: TIMER-ON button simply press this button again. Every press of either button changes the time setting by 1 minute. Holding down either button rapidly changes the time setting by 1 minute and then 10 minutes.
  • Page 14: Function Introduction For Combination Buttons

    Introduction for buttons on remote controller TURBO button Press this button to activate / deactivate the Turbo function which enables the blow strong heating air at super high fan speed. LIGHT button Press LIGHT button to turn on the display's light and press this button again to turn X-FAN button indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit.
  • Page 15 Function introduction for combination buttons Combination of "TEMP" and "CLOCK" buttons: About Energy-saving Function Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving function. Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function. Combination of "TEMP"...
  • Page 16: Operation Guide

    Operation guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
  • Page 17: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 18 Clean and maintenance Open panel Pull out the panel to a certain the water (below 45 ) to clean it, and then put it in a shady and cool place to dry. panel cover tightly. Note: operation environment, clean frequency can be increased.
  • Page 19 Clean and maintenance Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether circuit break, plug and socket are in good condition. 4. Check whether drainage pipe is damaged. Checking after use-season 1. Disconnect power supply. Notice for recovery 1.
  • Page 20: Malfunction

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still Phenomenon Check items Solution (such as static electricity,stable the plug after about 3min, and voltage)? then turn on the unit again. within the signal receiving range? Indoor unit Select proper angle and point...
  • Page 21: Malfunction Analysis

    Malfunction analysis Phenomenon Check items Solution fuse is burnt out? circuit break or fuse. Air condit- operate after stopping operation? on the unit again. for remote controller is correct? Mist is em- rapidly. After a while, indoor itted from temperature and humidity will idity is high? be decrease and mist will air outlet...
  • Page 22 Malfunction analysis Phenomenon Check items Solution Odours are such as furniture and cigarette, emitted etc. Air conditioner such as thunder, wireless power, and then turn on the operates nor- devices, etc. unit again. mally suddenly “Water turned off just now? the unit, which is a normal noise phenomenon.
  • Page 23 Malfunction analysis Error Code Note: Warning ’...
  • Page 24: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 15cm At least 15cm Space to the wall Drainage pipe...
  • Page 25: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: Selection of installation location...
  • Page 26: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. circuit break. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 27: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3.
  • Page 28 Installation of indoor unit Indoor outdoor Note: 5-10° Step four: outlet pipe 1. The pipe can be led out in the 2. When select leading out the pipe direction of right, rear right, left or from left or right, please cut off the rear left.
  • Page 29 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench 15~20 30~40 union nut 45~55 pipe torque wrench 60~65 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 30 Installation of indoor unit 2. Make the power connection wire go cable-cross through the cable-cross hole at the back hole the front side. power connection wire with wire clip. 09、12K: 18、24K: N(1) N(1) N(1) L1 L2 N(1) Outdoor unit connection Outdoor unit connection 09、...
  • Page 31 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 32: Check After Installation

    Check after installation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. It may cause condensation and water Is water drained well? dripping.
  • Page 33 1. Standard length of connection pipe 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe and max. high difference. Max length Max length Cooling Max height Cooling Max height of connec- of connec- capacity difference capacity difference tion pipe tion pipe 5000Btu/h...
  • Page 34 Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m)
  • Page 36 66129916602...

Table of Contents