Omron NYB17-*100 SERIES User Manual page 137

Ipc without operating system ny-series
Table of Contents

Advertisement

I/O Connector Wiring Procedure
Use the following procedure to wire the I/O connector.
1
Remove the sheath from the wires.
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
2
Remove the I/O connector from the Box PC.
3
Insert a screwdriver in the small groove above the cable entry
then push the wire all the way to the back of the cable opening
1
2
4
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.
NY-series Industrial Box PC Without Operating System User's Manual (W586)
7 mm
5 Installation
1
to unlock the cable entry and
.
2
5
5 - 41

Advertisement