Hide thumbs Also See for XM-5150GSX:
Table of Contents

Advertisement

XM-5150GSX
Bias Adjustment
Note : The Bias adjustment should be performed only if any of
Q106, Q107, Q206, Q207, Q306, Q307, Q406, Q407, Q506,
Q507, Q509 and Q510 are replaced.
Setting :
Stabilized
Power supply
B+,REM terminals
GND terminal
Procedure :
1. Rotate the variable resistors VR101, VR201, VR301, VR401
and VR501 fully in the clockwise direction to minimize the
idling current of the stabilized power supply.
2. The input signal is to be no signal.
3. Set the power voltage to +14.4 V, and turn the remote mode ON
(Connect between the REM terminal and B+ terminal).
4. Connect on digital voltmeter between each test points.
5. Adjust VR101, VR201, VR301 and VR401 so that the digital
voltmeter reading is 5 ± 0.5 mV.
6. Adjust VR501 so that the digital voltmeter reading is
3.5 ± 0.5 mV.
VR Ref. No.
Test points
VR101
TP101 and TP102
VR201
TP201 and TP202
VR301
TP301 and TP302
VR401
TP401 and TP402
VR501
TP501 and TP502
8
SECTION 3

ELECTRICAL ADJUSTMENT

Digital
Voltmeter
set
+
_
test points
Adjustment Location :
– AMP BOARD (COMPONENT SIDE) –
BIAS ADJUSTMENT
VR301
BIAS ADJUSTMENT
(REAR L-CH)
VR201
BIAS ADJUSTMENT
(FRONT R-CH)
VR101
BIAS ADJUSTMENT
(FRONT L-CH)
Test Point Location :
– AMP BOARD (CONDUCTOR SIDE) –
TP502
TP501
VR401
(REAR R-CH)
VR501
BIAS ADJUSTMENT
(SUB WOOFER)
TP401 TP402
TP301
TP302
TP201
TP202
TP101
TP102