Bias Adjustment
Note : In Bias Adjustment, adjust RV105 if any of Q108 through
Q113 are replaced. Adjust RV205 if any of Q208 through
Q213 are replaced.
Condition : This adjustment should be performed about one minute
after the remote mode is turned on at a room tempera-
ture of about 25°C.
Setting :
Stabilized
Power suppy
Procedure :
1. Turn the variable resistors RV105 (L-CH) and RV205 (R-CH)
full clockwise as seen from the component side to minimize the
bias current.
2. The input signal is to be no signal.
3. Apply the voltage to the B+ and REM terminals from the stabi-
lized power supply and gradually increase it up to 14.4 V while
checking for any unusual current.
4. For the XM-1502SX, adjust each of RV105 (L-CH) and RV205
(R-CH) so that the power current of the stabilized power supply
TE
L 13942296513
is increased in steps of 500 mA (total of 1 A). For the XM-
1902GX, adjust each of RV105 (L-CH) and RV205 (R-CH) so
that the power current is increased in steps of 600 mA (total of
1.2 A).
5. After adjustment, check that the power current is at 1.3 to 2.0 A.
Adjustment Location : Main board (component side)
– MAIN BOARD (COMPONENT SIDE) –
www
RV105
BIAS ADJUSTMENT
.
8
http://www.xiaoyu163.com
SECTION 3

ELECTRICAL ADJUSTMENT

B+,REM terminal
set
GND terminal
RV205
BIAS ADJUSTMENT
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Q Q
3
6 7
1 3
1 5
co
.
9 4
2 8
0 5
8
2 9
9 4
2 8
m
9 9
9 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm-1502sx

Table of Contents