Electrical Adjustment - Sony XM-1252GTR Service Manual

Hide thumbs Also See for XM-1252GTR:
Table of Contents

Advertisement

XM-1252GTR
Bias Adjustment
Note : In Bias Adjustment, adjust RV103 if any of Q108 through
Q111 are replaced. Adjust RV203 if any of Q208 through
Q211 are replaced.
Condition : This adjustment should be performed about one minute
after the remote mode is turned on at a room tempera-
ture of about 25°C.
Setting :
Stabilized
Power supply
Procedure :
1. Turn the variable resistors RV103 (L-CH) and RV203 (R-CH)
full clockwise as seen from the component side to minimize the
bias current.
2. The input signal is to be no signal.
3. Apply the voltage to the +12V and REM terminals from the sta-
bilized power supply and gradually increase it up to 14.4 V while
checking for any unusual current.
4. Adjust each of RV103 (L-CH) and RV203 (R-CH) so that the
power current of the stabilized power supply is increased in steps
of 550 mA.
Adjustment Location : AMP board (component side)
– AMP BOARD (COMPONENT SIDE) –
RV103
BIAS ADJUSTMENT
(L-CH)
10
SECTION 3

ELECTRICAL ADJUSTMENT

+12V, REM terminal
set
GND terminal
RV203
BIAS ADJUSTMENT
(R-CH)

Hide quick links: