Steps
9.Remove motor support
Twist off the tapping screws securing the
motor support, pull it upward and then
remove the motor support.
10.Remove isolation sheet
Twist off the screws connecting isolation sheet
and end plate of condenser and chassis, and
then remove the isolation sheet.
11.Remove 4-way valve
Unsolder the pipeline between compressor,
condenser, gas and liquid valve, and then
remove the 4-way valve. (Note: Release all
refrigerant before unsoldering.)
Procedure
motor support
isolation sheet
4-way valve