York DHP30NWB21SDCP30NWB21SDHP36NWB21SDCP36NWB21S Service Manual page 55

"p" series 30k - 36k 220v inverter-driven air conditioning units
Table of Contents

Advertisement

6. Malfunction of Communication E6
Start
Cut off power supply. Check if
connection line of IDU and ODU
and the wire inside electric box
are correctly connected.
Correct connection?
Main board matches
with display board? Main board of
IDU matches with that of ODU?
yes
Communication cord is damaged?
Replace IDU's
main board
Malfunction eliminated?
Connect the line
no
according to
wiring diagram.
yes
no
yes
no
no
yes
End
Malfunction eliminated?
no
Match correctly
Malfunction eliminated?
according to product
specification
no
Replace
Malfunction eliminated?
communication
cord
no
Replace ODU's
main board.
.
yes
yes
yes
48

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcp30csb21sDhp36csb21sDhp30csb21sDcp36csb21s

Table of Contents